ATS-AIC-2078

*Image above is for illustration purpose only..
ATS-AIC-2078
AI Chip Coolers / DLC Cold Plate

The ATS-AIC-2078 delivers efficient direct liquid cooling for high-density AI and HPC environments. It combines low thermal resistance with a compact mechanical design to support continuous high-power operation and easy integration into liquid cooling loops.

Features & Benefits
  • Designed for AMD Instinct MI300X and Intel Data Center GPU MAX 1550 applications
  • Thermal resistance as low as 0.006 °C/W (at 6 LPM)
  • Up to 9 kW thermal design power capability
  • Precision-machined copper for consistent heat transfer
  • Compact size: 100 × 120 × 29.1 mm
  • Cooling area: 80 × 100 mm
  • Weight: 1,111 g
  • Universal barb fittings for 8 mm OD / 5 mm ID tubing
Applications
  • AI training accelerators and high-power GPUs
  • Advanced HPC processors and computer platforms
  • High-density AI racks using direct-to-chip cooling
Specifications
Part Number Lifecycle
Status
Plate Dimension (mm) Weight (gr) Material Flow Rate
LPM(GPM) 1.0 (0.26)
Flow Rate
LPM(GPM) 2.0 (0.52)
Flow Rate
LPM(GPM) 3.0 (0.79)
Flow Rate
LPM(GPM) 4.0 (1.05)
Length Width Height R
(°C/W)
dP
kPA (psi)
R
(°C/W)
dP
kPA (psi)
R
(°C/W)
dP
kPA (psi)
R
(°C/W)
dP
kPA (psi)
ATS-AIC-2078 ACTIVE 100.0 120.0 29.1 1111 Cu 0.008 3.38 (0.49) 0.007 12.27 (1.78) 0.007 26.34 (3.82) 0.006 45.16 (6.55)
Thermal Performance
Schematic Image Thermal Resistance
Flow Rate
LPM(GPM)
R
(°C/W)
dP
kPA (psi)

*Image above is for illustration purpose only.
1.0 (0.26) 0.008 3.38 (0.49)
2.0 (0.52) 0.007 12.27 (1.78)
3.0 (0.79) 0.007 26.34 (3.82)
4.0 (1.05) 0.006 45.16 (6.55)
5.0 (1.32) 0.006 68.05(9.87)
6.0 (1.58) 0.006 95.77(13.89)
ATS-AIC-2078    (Data Sheet)
download data sheet
ATS-AIC-2078
CAD MODEL (Fused Model) - use for Form and Fit
Download CAD Model (Fused Model) (used for Form and Fit use)
RoHS & REACH Certificate download data sheet
Complete Your Liquid Loop with ATS

ATS has the products needed to design a complete liquid cooling loop : iCDMs (Industrial Cooling Distribution Modules), Tubed and High Performance Cold Plates to transfer and remove the heat from the source; Heat Exchangers to transfer heat from the liquid to the air with or without a fan; Chillers to circulate and condition the fluid in the system, Compact Refrigeration Modules for very high capacity cooling. In addition , ATS offers Flow Meters to measure the volumetric flow rate of the fluid in the system and Leak Detectors to notify users of any leaks in the system.