ATS-AIC-3709

*Image above is for illustration purpose only..
ATS-AIC-3709
AI Chip Coolers

The ArctiQ NIVIS Aura cold plate delivers next-generation liquid cooling for AMD SP5-based AI and HPC processors. Featuring an aluminium base and precision-machined fin core, Aura balances weight and performance for compact server environments.

Designed within a 118×92.4×30mm footprint, it offers efficient heat spreading and low thermal resistance without nickel plating for superior conductivity. CFD-validated geometry ensures consistent flow distribution and long-term reliability in demanding compute nodes.

Features & Benefits
  • Lightweight aluminum construction for easy system integration
  • Socket-specific interface for AMD SP5 architecture
  • Compact profile fits dense AI servers and testbeds
  • CFD-validated for repeatable, high-power operation
Applications
  • AI servers
  • data centers
  • high-performance computing
  • industrial automation
  • edge and embedded systems
  • automotive electronics
Specifications
Part Number Lifecycle
Status
Plate Dimension (mm) Weight (gr) Material Flow Rate
LPM(GPM) 1.0 (0.26)
Flow Rate
LPM(GPM) 2.0 (0.52)
Flow Rate
LPM(GPM) 3.0 (0.79)
Flow Rate
LPM(GPM) 4.0 (1.05)
Length Width Height R
(°C/W)
dP
kPA (psi)
R
(°C/W)
dP
kPA (psi)
R
(°C/W)
dP
kPA (psi)
R
(°C/W)
dP
kPA (psi)
ATS-AIC-3709 ACTIVE 118.0 92.4 31.0 188 AL 0.024 2.41 (0.35) 0.015 8.62 (1.25) 0.011 18.96 (2.75) 0.009 31.58 (4.58)
Thermal Performance
Schematic Image Thermal Resistance
Flow Rate
LPM(GPM)
R
(°C/W)
dP
kPA (psi)

*Image above is for illustration purpose only.
1.0 (0.26) 0.024 2.41 (0.35)
2.0 (0.52) 0.015 8.62 (1.25)
3.0 (0.79) 0.011 18.96 (2.75)
4.0 (1.05) 0.009 31.58 (4.58)
5.0 (1.32) 0.008 49.99(7.25)
6.0 (1.58) 0.007 71.71(10.4)
ATS-AIC-3709    (Data Sheet)
download data sheet
RoHS & REACH Certificate download data sheet
Complete Your Liquid Loop with ATS

ATS has the products needed to design a complete liquid cooling loop : iCDMs (Industrial Cooling Distribution Modules), Tubed and High Performance Cold Plates to transfer and remove the heat from the source; Heat Exchangers to transfer heat from the liquid to the air with or without a fan; Chillers to circulate and condition the fluid in the system, Compact Refrigeration Modules for very high capacity cooling. In addition , ATS offers Flow Meters to measure the volumetric flow rate of the fluid in the system and Leak Detectors to notify users of any leaks in the system.