{"id":8309,"date":"2017-09-22T13:47:19","date_gmt":"2017-09-22T17:47:19","guid":{"rendered":"http:\/\/www.qats.com\/cms\/?p=8309"},"modified":"2018-02-26T10:53:54","modified_gmt":"2018-02-26T14:53:54","slug":"in-the-ats-labs-where-thermal-solutions-advance-to-meet-industry-demands","status":"publish","type":"post","link":"https:\/\/www.qats.com\/cms\/2017\/09\/22\/in-the-ats-labs-where-thermal-solutions-advance-to-meet-industry-demands\/","title":{"rendered":"In the ATS Labs \u2013 Where Thermal Solutions Advance to Meet Industry Demands"},"content":{"rendered":"<p>Thermal management innovations need to match the rapid pace at which the electronics industry is advancing. As consumers demand new and more powerful devices or greater amounts of information at faster speeds, cooling solutions of the past will not be enough. Today\u2019s cooling solutions must be smaller, lighter, and offer higher performance, but also need to be cost-effective, meet demanding project specifications, and be reliable for many years.<\/p>\n<p><a href=\"https:\/\/www.qats.com\/\">Advanced Thermal Solutions, Inc. (ATS)<\/a> understands the importance of creating cutting-edge thermal solutions for its customers and has geared its <a href=\"https:\/\/www.qats.com\/Consulting\/Custom-Cooling-Solutions\">thermal design capability<\/a> and its research and development to match the innovations taking place in electronics design.<\/p>\n<div id=\"attachment_8315\" style=\"width: 2602px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/www.qats.com\/cms\/wp-content\/uploads\/Priyanka-Lab.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-8315\" class=\"size-full wp-image-8315\" src=\"http:\/\/www.qats.com\/cms\/wp-content\/uploads\/Priyanka-Lab.jpg\" alt=\"ATS Labs\" width=\"2592\" height=\"1728\" srcset=\"https:\/\/www.qats.com\/cms\/wp-content\/uploads\/Priyanka-Lab.jpg 2592w, https:\/\/www.qats.com\/cms\/wp-content\/uploads\/Priyanka-Lab-300x200.jpg 300w, https:\/\/www.qats.com\/cms\/wp-content\/uploads\/Priyanka-Lab-1024x683.jpg 1024w, https:\/\/www.qats.com\/cms\/wp-content\/uploads\/Priyanka-Lab-800x533.jpg 800w\" sizes=\"auto, (max-width: 2592px) 100vw, 2592px\" \/><\/a><p id=\"caption-attachment-8315\" class=\"wp-caption-text\">An ATS engineer assembles a rig for testing cold plates in one of ATS&#8217; six state-of-the-art labs. (Advanced Thermal Solutions, Inc.)<\/p><\/div>\n<p>To meet the need for innovative solutions, ATS engineers are hard at work in the company\u2019s <a href=\"https:\/\/www.qats.com\/Consulting\/Lab-Capabilities\">six state-of-the-art laboratories at the ATS headquarters<\/a>, located in Norwood, Mass. (south of Boston). Thermal issues of all kinds are recognized, broken down, and resolved and cooling solutions are designed, simulated, <a href=\"https:\/\/www.qats.com\/Services\/Rapid-Prototyping\">prototyped<\/a>, and rigorously tested in these research-grade facilities.<\/p>\n<p>When someone thinks of a research lab, the initial picture is scientists in white coats working for major corporations, such as IBM, Microsoft, or Google, but the development of new ideas is an essential tool for any company in the technology field. Working with empirical tests in a lab environment pushes concepts from the white board or the computer screen to reality. There comes a time when engineers need to produce tangible data to ensure that a design works as planned.<\/p>\n<p>ATS thermal engineers are no different. They use <a href=\"https:\/\/www.qats.com\/Products\/Instruments\">state-of-the-art instruments<\/a> and software in each of the six labs to conduct a long list of characterization, quality-assurance, and <a href=\"https:\/\/www.qats.com\/Consulting\/Testing-and-Validation\">validation tests<\/a>. In addition to finding custom cooling solutions for customers, ATS engineers produce thermal management products for commercial uses, including a variety of next generation <a href=\"https:\/\/www.qats.com\/Heat-Sink\">heat sink<\/a>, <a href=\"https:\/\/www.qats.com\/Consulting\/Heat-Pipe-and-Vapor-Chamber-Design\">heat pipe, vapor chamber<\/a>, and <a href=\"https:\/\/www.qats.com\/Consulting\/Liquid-Cooling-System-Design\">liquid cooling<\/a> designs.<\/p>\n<div id=\"attachment_8732\" style=\"width: 4522px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/www.qats.com\/cms\/wp-content\/uploads\/Lab-Equipment-1.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-8732\" src=\"http:\/\/www.qats.com\/cms\/wp-content\/uploads\/Lab-Equipment-1.jpg\" alt=\"\" width=\"4512\" height=\"3456\" class=\"size-full wp-image-8732\" srcset=\"https:\/\/www.qats.com\/cms\/wp-content\/uploads\/Lab-Equipment-1.jpg 4512w, https:\/\/www.qats.com\/cms\/wp-content\/uploads\/Lab-Equipment-1-300x230.jpg 300w, https:\/\/www.qats.com\/cms\/wp-content\/uploads\/Lab-Equipment-1-1024x784.jpg 1024w, https:\/\/www.qats.com\/cms\/wp-content\/uploads\/Lab-Equipment-1-800x613.jpg 800w\" sizes=\"auto, (max-width: 4512px) 100vw, 4512px\" \/><\/a><p id=\"caption-attachment-8732\" class=\"wp-caption-text\">Engineers test ATS instruments using a wind tunnel and sensors in the Characterization Lab. (Advanced Thermal Solutions, Inc.)<\/p><\/div>\n<p>Among the most common tests performed in the ATS labs are:<\/p>\n<p>\u2022 Measurements of air velocity, direction, pressure and temperature;<br \/>\n\u2022 Characterization of heat sink designs, fans and cold plates<br \/>\n\u2022 Flow visualization of liquid and air flow<br \/>\n\u2022 Image visualization characterization using infrared and liquid crystal thermography.<\/p>\n<p>Many of the instruments that these tests are performed on were designed and fabricated by ATS. That includes <a href=\"https:\/\/www.qats.com\/Products\/Wind-Tunnels\">open-loop, closed-loop, and bench-top wind tunnels<\/a>; <a href=\"https:\/\/www.qats.com\/Products\/Instruments\/Temperature-and-Velocity-Measurement\/iQ-200\">the award-winning iQ-200&#x2122;<\/a>, which measures air temperature, velocity, and pressure with one instrument; and the <a href=\"https:\/\/www.qats.com\/Products\/Instruments\/Surface-Thermography\/thermVIEW\">thermVIEW&#x2122; liquid crystal thermography system<\/a>. Engineers also use specially-designed sensors, <a href=\"https:\/\/www.qats.com\/Products\/Instruments\/Temperature-and-Velocity-Measurement\/Sensors\/Candlestick-Sensor\">such as the ATS Candlestick Sensor<\/a>, to get the most accurate analysis possible.<\/p>\n<div id=\"attachment_8316\" style=\"width: 5050px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/www.qats.com\/cms\/wp-content\/uploads\/Smoke-Flow-1.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-8316\" class=\"size-full wp-image-8316\" src=\"http:\/\/www.qats.com\/cms\/wp-content\/uploads\/Smoke-Flow-1.jpg\" alt=\"\" width=\"5040\" height=\"2772\" srcset=\"https:\/\/www.qats.com\/cms\/wp-content\/uploads\/Smoke-Flow-1.jpg 5040w, https:\/\/www.qats.com\/cms\/wp-content\/uploads\/Smoke-Flow-1-300x165.jpg 300w, https:\/\/www.qats.com\/cms\/wp-content\/uploads\/Smoke-Flow-1-1024x563.jpg 1024w, https:\/\/www.qats.com\/cms\/wp-content\/uploads\/Smoke-Flow-1-800x440.jpg 800w\" sizes=\"auto, (max-width: 5040px) 100vw, 5040px\" \/><\/a><p id=\"caption-attachment-8316\" class=\"wp-caption-text\">Smoke flow visualization tests run in ATS wind tunnels demonstrate how air flows through a system. (Advanced Thermal Solutions, Inc.)<\/p><\/div>\n<p><a href=\"https:\/\/www.qats.com\/Products\/Heat-Pipes\">Heat pipes<\/a> and vapor chambers are increasingly common cooling solutions, particularly for mobile devices and other consumer electronics, and ATS engineers are working to expand the company\u2019s offerings for these solutions and to develop next generation technology that optimizes the thermal performance of these products. This research involves <a href=\"https:\/\/www.qats.com\/cms\/2017\/02\/02\/how-did-thermal-performance-of-aluminum-heat-sinks-compare-to-copper\/\">advanced materials<\/a>, new fabrication methods, performance testing, and innovative designs that are ready for <a href=\"https:\/\/www.qats.com\/Services\/Fabrication-Capabilities\">mass production<\/a>.<\/p>\n<div id=\"attachment_8312\" style=\"width: 1186px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/www.qats.com\/cms\/wp-content\/uploads\/IMG_5135.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-8312\" class=\"size-full wp-image-8312\" src=\"http:\/\/www.qats.com\/cms\/wp-content\/uploads\/IMG_5135.jpg\" alt=\"\" width=\"1176\" height=\"1596\" srcset=\"https:\/\/www.qats.com\/cms\/wp-content\/uploads\/IMG_5135.jpg 1176w, https:\/\/www.qats.com\/cms\/wp-content\/uploads\/IMG_5135-221x300.jpg 221w, https:\/\/www.qats.com\/cms\/wp-content\/uploads\/IMG_5135-755x1024.jpg 755w, https:\/\/www.qats.com\/cms\/wp-content\/uploads\/IMG_5135-589x800.jpg 589w\" sizes=\"auto, (max-width: 1176px) 100vw, 1176px\" \/><\/a><p id=\"caption-attachment-8312\" class=\"wp-caption-text\">ATS engineer Vineet Barot sets up a thermal imaging camera for temperature mapping studies in the lab. (Advanced Thermal Solutions. Inc.)<\/p><\/div>\n<p>ATS has also developed products to meet the growing demand across the electronics industry for liquid cooling systems. From new designs for <a href=\"https:\/\/www.qats.com\/Products\/Liquid-Cooling\/Chillers\">recirculating and immersion chillers<\/a> to <a href=\"https:\/\/www.qats.com\/Products\/Liquid-Cooling\/Cold-Plates\">multi-channel cold plates<\/a> to <a href=\"https:\/\/www.qats.com\/Products\/Liquid-Cooling\/Heat-Exchangers\">tube-to-fin heat exchangers<\/a>, ATS is continuing to expand its line of liquid cooling solutions to maximize the transfer of heat from liquid to air and <a href=\"https:\/\/www.qats.com\/cms\/2017\/05\/10\/fin-optimization-heat-sinks-heat-exchangers\/\">researching new manufacturing methods<\/a>, advanced materials, and other methods of enhancing the technology.<\/p>\n<p>As liquid cooling technology has grown, ATS has met this demand with new instruments and lab capabilities, such as the <a href=\"https:\/\/www.qats.com\/Products\/Instruments\/Specialty-Instruments\/iFLOW-200\">iFLOW-200&#x2122;<\/a>, which measures a cold plate\u2019s thermal and hydraulic characteristics, and full liquid loops to test ATS products under real-world conditions.<\/p>\n<div id=\"attachment_8314\" style=\"width: 4534px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/www.qats.com\/cms\/wp-content\/uploads\/IMG_9986.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-8314\" class=\"size-full wp-image-8314\" src=\"http:\/\/www.qats.com\/cms\/wp-content\/uploads\/IMG_9986.jpg\" alt=\"ATS Labs\" width=\"4524\" height=\"3276\" srcset=\"https:\/\/www.qats.com\/cms\/wp-content\/uploads\/IMG_9986.jpg 4524w, https:\/\/www.qats.com\/cms\/wp-content\/uploads\/IMG_9986-300x217.jpg 300w, https:\/\/www.qats.com\/cms\/wp-content\/uploads\/IMG_9986-1024x742.jpg 1024w, https:\/\/www.qats.com\/cms\/wp-content\/uploads\/IMG_9986-800x579.jpg 800w\" sizes=\"auto, (max-width: 4524px) 100vw, 4524px\" \/><\/a><p id=\"caption-attachment-8314\" class=\"wp-caption-text\">ATS engineer Reza Azizian (right) works with intern Vladislav Blyakhman on a liquid cooling loop in the lab. (Advanced Thermal Solutions, Inc.)<\/p><\/div>\n<p>The labs at ATS are up to even the toughest electronics cooling challenges that the company\u2019s global customers present. Thanks to its extensive lab facilities, ATS has provided thousands of satisfied customers with the state-of-the-art thermal solutions that they demand.<\/p>\n<p><em>For more information about Advanced Thermal Solutions, Inc. (ATS) thermal management consulting and design services, visit <a href=\"https:\/\/www.qats.com\/Consulting\">www.qats.com\/consulting<\/a> or contact ATS at 781.769.2800 or <a href=\"mailto:ats-hq@qats.com\">ats-hq@qats.com<\/a>.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Thermal management innovations need to match the rapid pace at which the electronics industry is advancing. As consumers demand new and more powerful devices or greater amounts of information at faster speeds, cooling solutions of the past will not be &hellip; <a href=\"https:\/\/www.qats.com\/cms\/2017\/09\/22\/in-the-ats-labs-where-thermal-solutions-advance-to-meet-industry-demands\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1001004,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[13,34,58,64],"tags":[849,81,217,325,101,553,107,178,126,298,850,297],"class_list":["post-8309","post","type-post","status-publish","format-standard","hentry","category-consulting","category-instrument","category-thermal-analysis-2","category-thermal-research","tag-chillers","tag-cold-plates-2","tag-heat-exchangers","tag-heat-pipes","tag-heat-sinks-2","tag-instruments","tag-liquid-cooling-2","tag-sensors","tag-thermal-analysis","tag-thermal-testing","tag-vapor-chambers","tag-wind-tunnels"],"_links":{"self":[{"href":"https:\/\/www.qats.com\/cms\/wp-json\/wp\/v2\/posts\/8309","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qats.com\/cms\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.qats.com\/cms\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.qats.com\/cms\/wp-json\/wp\/v2\/users\/1001004"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qats.com\/cms\/wp-json\/wp\/v2\/comments?post=8309"}],"version-history":[{"count":12,"href":"https:\/\/www.qats.com\/cms\/wp-json\/wp\/v2\/posts\/8309\/revisions"}],"predecessor-version":[{"id":8733,"href":"https:\/\/www.qats.com\/cms\/wp-json\/wp\/v2\/posts\/8309\/revisions\/8733"}],"wp:attachment":[{"href":"https:\/\/www.qats.com\/cms\/wp-json\/wp\/v2\/media?parent=8309"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.qats.com\/cms\/wp-json\/wp\/v2\/categories?post=8309"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.qats.com\/cms\/wp-json\/wp\/v2\/tags?post=8309"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}