Category Archives: thermal management

Vapor Chambers and Their Use in Thermal Management (part 2 of 2)

In part 1 of our 2 part series on vapor chambers, we covered what a vapor chamber is and their effectiveness. Here in part 2, we’ll cover more about why vapor chambers are effective, as well as their application in thermal management of electronics.

Figure 2 gives a schematic view of a typical vapor chamber. Its successful performance depends on many factors, as explained in the following paragraphs.


Vapor Chamber for thermal management

Figure 2. Schematic of a Vapor Chamber

The thermal conductivity of a vapor chambers wick has a strong influence on its overall effectiveness. Wicks are typically made from copper powder. Heat must travel through the wick structure to vaporize the water. The low thermal conductivity of water compared to that of copper powder can degrade the chambers performance.

The effective thermal conductivity of a wick can be expressed as shown below [2]:
Vapor Chamber Formula 1

Where

Kw = Wick effective thermal conductivity

Kl = Water thermal conductivity, W/moC

Ks = Copper thermal conductivity, W/moC

Rc = Capillary radius, m

Rs = Particle sphere radius, m

The above equation yields a value of 40 W/moC for water inside a sintered copper wick.

Another variable to consider is the effective thermal conductivity of the vapor space [3]:

Vapor Chamber Formula 2

Where

Kvap = Vapor space effective thermal conductivity

Hfg = Heat of vaporization, J/Kg

P = Pressure, N/m2

vapor chamber forumla 4 = Density, Kg/m3

d = Vapor space thickness, mm

R = Gas constant per unit mass, J/K.Kg

Vapor Chamber Formula 5 = Dynamic viscosity, N·sec/m2

T = Vapor temperature, oC

As shown in Figure 3 below, when plotted against temperature, the above equation demonstrates that the effective vapor space conductivity is very low at low temperatures. This has a significant implication for low heat flux or start up conditions [4]

Vapor Chamber Graph 1

Figure 3: Effective Thermal Conductivity of Vapor Space as a Function of Temperature [1]

To address the effects of different variables on the performance of a vapor chamber, a conduction model was put together as shown in Figure 4 [4]. In this model, a 10 x 10 mm heat source was mounted on a 42.5 x 42.5 mm ceramic chip carrier. The model was analyzed using Flotherm computational fluid dynamics (CFD) software. Different layers of the resistance network were constructed using their effective thermal conductivities, which were known or could be calculated as shown in the previous equations. The vapor chamber was modeled as a combination of the vapor chamber wall, wick structure, and vapor space. An effective heat transfer coefficient of 1,400 W/m2K was assigned based on the performance of the heat sink. The ambient air temperature was assumed to be 35 oC and a uniform heat flux of 100 W/cm2 was applied at the base. Figures 5 and 6 reveal some interesting findings about the performance of the vapor chamber.

Vapor Chamber in Thermal Management Figure 4Figure 4: Schematic of a Vapor Chamber Physical Model for CFD

Figure 5 shows the junction temperature (Tj) as a function of wick effective thermal conductivity. The vapor space thermal conductivity was assumed to be 30,000 W/mK. The graph shows that the chip junction temperature drops from 97 oC to 93.5 oC for wick conductivities of 30 and 60 W/mK, respectively. In other words, the performance of the vapor chamber is strongly influenced by wick thermal conductivity. However, Figure 6 shows that junction temperature is a very weak function of vapor space thermal conductivity. This is due to the fact that even an equivalent thermal conductivity of 5,000 W/mK, the lowest on the X-axis, is still a large number. However, if the vapor temperature is below a certain value, such as 35 oC, then the vapor space effective thermal conductivity will drop drastically, impacting the junction temperature.

Vapor Chamber Graph 2

Figure 5: Junction Temperature as a Function of Wick Effective Thermal Conductivity[1]

Vapor Chamber for Thermal Management GraphFigure 6: Junction Temperature as a Function of Vapor Space Thermal Conductivity [1]

Figure 7 shows junction and case temperatures as a function of vapor chamber size (lid) using examples that compare a solid heat sink base and a vapor chamber. The graph shows that for this particular configuration, a solid copper block outperforms a vapor chamber below the 40 mm lid size. But, above 40 mm the vapor chamber is a better choice. The superior performance of the VC over solid copper is due to its enhanced lateral heat spreading on larger surfaces.

Vapor Chamber for Thermal Managment Figure 7

Figure 7: Junction Temperature as a Function of Lid Size for Vapor Chamber and Solid Copper Base [1]

Figure 8 shows the temperature as a function of lid size for heat transfer coefficients of 400 and 50,000 W/m2K. These extreme values of heat transfer coefficients represent low performance and very high performance heat sinks. The graph shows that with a low performance heat sink, the cross over point between the copper block and the vapor chamber is at 40 mm. From here the VC starts to outperform the copper block. For a very high heat transfer coefficient, such as with a liquid cooled cold plate, the size of the VC needs to be much larger to have an advantage over the copper block. In other words, if a large (80 x 80 mm) liquid cooled plate is used, a solid copper block will provide the same performance as a vapor chamber.

Vapor Chamber Figure 8

Figure 8: Junction Temperature as a Function of Lid Size for Vapor Chamber and Solid Copper Base for 400 and 50,000 W/m2K Heat Transfer Coefficients [1]

Conclusion

This article shows that while a vapor chamber presents exciting technology, some calculations should be made to justify its use. As shown above, in some situations a solid copper block might provide better thermal performance than a VC. To use a VC instead of solid copper must be justified, for example, to reduce weight. Some vapor chambers have a power limit of 500 Watts. Exceeding this value might cause a dry out, as with a heat pipe, and could increase the vapor temperature and the pressure. The increase in internal pressure can deform the VC surfaces, or cause leakage from the welded joints. Other factors that need to be addressed include, cost, availability, and in special cases, the vapor chambers manufacturability.

References:

  1. Mehl, D., Dussinger, P., Use of Vapor Chambers for Thermal Management, ThermaCore Inc.
  2. Chi, S., Heat Pipe Theory and Practice, Hemisphere Publishing, 1976.
  3. Prasher, R., A Simplified Conduction Based Modeling Scheme for Design Sensitivity Study of Thermal Solution Utilizing Heat Pipe and Vapor Chamber Technology, J. Electronics Packaging, Vol. 125, 2003.
  4. Wei, X, Sikka, K., Modeling of Vapor Chamber as Heat Spreading Devices, ITHERM 2006.

Vapor Chambers and Their Use in Thermal Management (part 1 of 2)

We’re running a two part series at the ATS Thermal Blog this week on vapor chambers, what they are, how they work, and their use in thermal management.  In part 1 we’ll cover what a vapor chamber is and their effectiveness.

Increasing heat fluxes and decreasing sizes pose a major challenge for keeping electronic components below their critical junction temperatures. To cool a high power device with a small footprint requires a heat sink larger than the component. This size difference creates an added thermal resistance, called spreading resistance, which is usually in the same order of magnitude as the heat sink thermal resistance.

Spreading resistance is observed in combinations of very high performance heat sinks and small heat source sizes, e.g. 10 x 10 or 15 x 15 mm. There are many ways to reduce this added resistance. One is to use a highly conductive material, such as copper. It has a smaller spreading resistance than aluminum, although it is much heavier and costlier. Other ways to lower spreading resistance include the use of heat pipes, liquid cooling, vapor chambers, micro TECs (thermoelectric coolers), and the recently developed Forced Thermal Spreader (Advanced Thermal Solutions, Inc.). The focus of this article, however, will be the use of vapor chambers.

A vapor chamber (VC) is basically a flat heat pipe that can be part of the base of a heat sink. It is vacuumed and then injected with just enough liquid, e.g. water, to wet the wick. The theory of operation for a vapor chamber is the same as for a heat pipe. The heat source causes the liquid to vaporize on the evaporator side. The resulting pressure increase in this area forces the vapor into the condenser side, which is the base of the heat sink. Here, the vapor transfers the heat to the heat sink, and it then condenses back to liquid. The liquid is pumped back to the base through the capillary action of the wick structure.

It has been shown that for electronics cooling applications, sintered copper and water are the best choices for the chamber material and its internal liquid. The advantages of water are its high thermal conductivity, high surface tension, and non-toxicity.

A vapor chamber is generally used to spread heat more uniformly than with a solid metal block. This is due to the chambers high equivalent thermal conductivity. Figure 1 shows the temperature distribution in two heat sinks: one has a solid base and the other has a vapor chamber in its base. The heat sink without the VC shows temperature concentrated on top of the heat source, while the major portion of the heat sink is running cold. The result is low thermal performance. On the other hand, the heat sink with the VC in its base shows a very uniform temperature distribution. The very high equivalent thermal conductivity of the vapor chamber has spread the heat uniformly, leading to more efficiency from the heat sink.

Advanced Thermal Solutions Vapor Chamber 1Figure 1. Schematic View of Heat Sinks with
(a) Solid Base and (b) Vapor Chamber Base [1]

The effective thermal conductivity of heat pipes and vapor chambers is estimated to be 5,000-20,000 W/moC [1]. It should be noted that when a heat pipe is attached to the base of a heat sink the extra interfacial resistance from this bonding can degrade the effective thermal conductivity to about 4,000 W/moC. A vapor chamber, however, has the advantage of being part of the heat sink base, eliminating the interfacial resistance.

In part 2 of our two part series on vapor chambers, we’ll cover more about why vapor chambers are effective, as well as their application in thermal management of electronics.

References:

  1. Mehl, D., Dussinger, P., Use of Vapor Chambers for Thermal Management, ThermaCore Inc.
  2. Chi, S., Heat Pipe Theory and Practice, Hemisphere Publishing, 1976.
  3. Prasher, R., A Simplified Conduction Based Modeling Scheme for Design Sensitivity Study of Thermal Solution Utilizing Heat Pipe and Vapor Chamber Technology, J. Electronics Packaging, Vol. 125, 2003.
  4. Wei, X, Sikka, K., Modeling of Vapor Chamber as Heat Spreading Devices, ITHERM 2006.

OEM cuts project costs, improves MTBF using ATS heat sink solution: An ATS Thermal Labs Case Study

A California based optical networking company asked ATS for thermal management services to manage excess heat in a telecom cabinet.

The OEM’s optical transport board employed 16 heat sinks, two of which were ATS maxiFLOWTM heat sinks. These were attached to hot processors using the ATS maxiGRIPTM clip system. The other heat sinks were all 15mm x 15mm straight fin designs attached to various semiconductors using a thermally conductive epoxy. The thermal epoxy was meant to provide a secure, mechanical bond for mounting the heat sinks to the ICs on their circuit board. But the results were not as expected. The epoxy-attached heat sinks began falling off the PCBs in both field and lab deployments.

The customer’s team considered alternative approaches, including thermal adhesive tape but were unable to find a suitable solution. ATS was brought onto the team to find the problems root cause and provide a suitable solution that met the OEMs technical requirements and cost constraints.

ATS analyzed the customer’s circuit boards, heat sinks, and the thermal epoxy, and completed thermal modeling and analysis of the application. Following this approach, ATS recommended using the originally designed-in heat sinks. The thermal analysis showed their performance was satisfactory, with margin, for this application. ATS recommended a heat sink clip be used instead of thermal epoxy. The ATS superGRIPTM heat sink clip and a phase change thermal interface material were then introduced.

ATS supplied early samples of a standard superGRIP and 15mm x 15mm straight fin heat sink. After physical testing, both thermal teams came to the conclusion that the new solution would improve both the mechanical attachment and thermal performance. However, the standard off the shelf superGRIP was not the right dimensions for a best fit; critical to it’s mechanical attachment and capability to apply the right amount of pressure for phase change material to be effective. That correct amount of pressure is critical to phase change material so it can give the best heat transfer from the semiconductor to the heat sink.

ATS developed a custom superGRIP for the application, and upon further testing found the combination of straight fin heat sink, superGRIP, and phase change interface to meet the design requirements.

The result of this partnering work between ATS and their customer were:

  • Reduced cost of production as epoxy required more training to use and had a shelf life
  • Passing of NEBS shock and vibration testing
  • Increased product MTBF and reliability
  • The OEM was able to ship their product to gain sales

If your team is facing a similar dilemma, contact us at ATS ; Phone: 781-769-2800, email: [email protected] or visit our web site at http://www.qats.com. You can also click to ATS’s You Tube Channel to see a demo of our superGRIP heat sink clip

Managing to the Junction Temperature for Thermal Management of Telecom and Datacom Equipment

Kontron has just released their first Cavium OCTEON® II AdvancedMC packet processor module, the AM2411. Kontron’s module features the Cavium Networks Octeon II CPU. It’s an incredibly powerful network processor and Kontron has really taken advantage of it to create an industry thumping feature set. This kind of product will serve telecomm companies very well in creating 4G networks using either LTE or WiMAX. The board designers clearly made the product durable as it has passed testing for Telcordia GR-1089, GR-63, IEC 60950-1, EN/CSA/ UL 60950-1. And this quote from their datasheet really tells it all regarding the 4211’s design point, quality: “This board is designed to meet NEBS Level 3, Earthquake Zone 4”

Board quality and specifications are not going to be a question with this product!

What is going to be a consideration is what this product is like in a chassis full of other boards operating at peak performance. There is no question Kontron has done a great job designing their board, but, their board now becomes a component in an integrated system. Such an integration of Commercial Off the Shelf Components (COTS)is almost always a challenge across a number of technical areas.

Trenton Technologies wrote a bit on this in their blog back in July of 2010 with their post, “Can You Really Simplify Integration of Industrial Computer Systems?” In that post they noted that 6 key factors to decided if a COTS solution could be used in an application, those six points are:

  1. System location requirements
  2. Projected service life of the system
  3. Number of option cards needed in the computer
  4. System expansion requirements
  5. System power and fail-over requirements
  6. System O/S and application software solution requirements

But the one piece they missed was the overall system thermal load. So let’s talk about that a bit. First, the key target temperature to keep in mind is the junction temperature. The junction temperature is the temperature of the silicon die within the package of the device when the device is powered. The junction temperature can also be referred to as the operating temperature. The goal of thermal management is to manage the heat to the junction temperature.

What is semiconductor junction temperature and how do you manage to it

A successful thermal design requires that the junction temperatures of all critical devices in a system be sufficiently below their critical level in the worst-case ambient temperature. Otherwise, higher temperatures may result in data transmission bit errors and/or a decrease in a system’s life expectancy. Thermal coupling and non-uniform PCB layout make this determination a complicated process.

The list of thermal parameters that a complete system has to manage to help reduce the junction temperature on a device are pretty long:

  1. Thermal coupling within the system and surrounding equipment
  2. System standardization (e.g., the ATCA Standard)
  3. Constrained space
  4. EMI/EMC requirements for high frequency devices, boards and packaging
  5. Acoustic noise/li>
  6. Limited air flow
  7. Rigid performance standards (e.g., 72 hours operation at 55oC)
  8. Non-uniform power distribution and congested PCBs
  9. Service Level Agreement(e.g., system operational within 4 hours of failure)

The following table shows the approach, domain, anticipated results, and the needed tools to successfully obtain the junction temperature of a device in the system.

Solution Order Package Level Expected Results Requirements and Tools
First System System flow distribution and boundary conditions for the card racks, T, V, and Pressure Measurement or
Second’ Card Rack (chassis) Boundary conditions for the PCB, and thermal coupling between the board and the rack Measurement or Simulation (CFD) and solid modeling (temperature gradient in the solid)
Third Board (PCB) Boundary conditions for the component on heat transfer and fluid flow Measurement of fluid flow distribution and board properties and board level solid modeling
Fourth Component (device or module) Boundary conditions for the Die (Tj) and its cooling solution Fluid flow and temperature measurement equipment; Heat sink; Interface materials and their properties;Solid modeling;Package material properties

Once the junction temperature is obtained by using two independent methods, it must be ensured that there is at least a 10% margin of safety in the design. Therefore, the following equation must be satisfied.

Junction temperature formula

Where

Tj, calculated = junction temperature as the result of above calculation.
Tj, spec = critical junction temperature specified by the manufacturer.
Ta, reference = reference ambient or approach air temperature.

With a properly determined junction temperature in hand, a cooling method can be selected for maintaining the desired performance. Depending on the data obtained from the table, we can choose from these options:

  • Natural convection
  • Forced convection (air-mover)
  • Active air cooling (not very common)
  • Jet impingement (air or liquid)
  • Advanced systems (liquid or refrigeration)

Although cooling by air is the most common and preferred system, liquid cooling has been used in unique circumstances. Regardless of the method selected, every cooling decision should consider the following parameters:

  • Cooling capacity – does it satisfy the junction temperature requirements?
  • Size – does it comply with the packaging requirements?
  • Regulatory requirements – does it meet the system and site implementation requirements (e.g., NEBS) ?
  • Reliability – does it meet the expected life requirements?
  • Budget – does it comply with the cost constraints imposed on the system?
  • Market availability – is it readily available? Can supply-chain requirements be met?

Obtaining a successful cooling solution is made possible by combining methodical thermal analysis (as delineated in our table) with the results from at least two independent approaches, and taking into account the above system parameters.

What is a thermal barrier and how do you apply them to thermal management problems?

Thermal barriers used in developing thermal management solutions don’t get the same mention in engineering conversations as say heat sinks, thermal resistance, fans or even thermal epoxy! You generally don’t want to put anything up as a potential “barrier” to any air movement, since that would defeat the purpose of your thermal management in the first place. But what is a thermal barrier and why would you use it?

A thermal barrier is a a material used to reduce the movement of heat. In this way, it can be used to shield some components from others that are very high heat. This causes the heat from a source to become spread out, and you shield the components on the other side. For example, a mobile phone might use several pieces of flexible graphite to create a thermal barrier shielding some components from the high heat of others. A netbook or tablet could conceivably employ thermal barriers as well, so that the heat from the CPU doesn’t negatively impact the other components being shielded.

Thermal barriers may also be used when the heat transfer from the higher heat device might cause another device to be thermally out of specification, resulting in the chips thermal circuit to trip, shutting down the device or reducing it’s performance potential.

Where can thermal professionals get such a material? There are a few sources and we’ll list just a few here:

  • GrafTech makes several grades of flexible graphite, which have thermal conductivities of 300 to 1500 W/m-K in plane, and under 15 through plane.
  • Zircotec has a number of ceramic products that look promising