How to apply adaptive cooling to keep cloud computing data centers cool

Data centers are the heart of cloud computing. They are impressive computing systems in and of themselves. But with so much CPU power generating so much heat how can thermal engineers architect them for optimal thermal management? One solution is adaptive cooling. Our thermal engineering team has written a white paper addressing adaptive cooling and it can be yours without cost or obligation, just click to this link: “ATS White Paper: Adaptive Cooling in Data Centers“

How to Control Spreading Thermal Resistance

One of the basic concepts of electronics cooling is effective transfer of heat from semiconductor devices to the ambient using heat sinks or other cooling technologies. The effectiveness of this approach depends on a systems total thermal resistance, which is composed of discrete thermal resistances on the path of heat from the source to the ambient. One of these resistances is spreading resistance.

Spreading resistance occurs whenever a small heat source comes in contact with the base of a larger heat sink. The heat does not distribute uniformly through the heat sink base, and consequently does not transfer efficiently to the fins for convective cooling. Figure 1 shows a CFdesign® simulation solution for such an occurrence. The spreading resistance phenomenon is shown by how the heat travels through the center of a heat sink base causing a large temperature gradient between the center and edges of the heat sink.

graph showing temperature distribution at the base of a heat sinkFigure 1: CFdesign solution showing temperature distribution
at the base of a heat sink

Spreading resistance is an increasingly important issue in thermal management as microelectronic packages become more powerful and compact and larger heat sinks are required to cool these devices. In high heat flux applications, spreading resistance can comprise 60 to 70% of the total thermal resistance.

A good estimate of spreading resistance is required to manage heat effectively using conventional air-cooled heat sinks. There have been a number of theoretical and experimental studies to estimate spreading resistance. Two of the most notable methods belong to Yovanovich et al. [1] and to Gordon N. Ellison [2].

While these extensive studies cover all aspects of spreading resistance, they involve cumbersome infinite series and complicated coefficient terms.  (click the link to read the rest of our article here on our electronics cooling blog)

Continue reading →

Give us 60 minutes and we’ll give you a cooler datacenter!

Give us 60 minutes and we’ll give you a cooler datacenter!  That’s right, our webinar on October 27, “Tools and Techniques for the Thermal Management of Small, Medium and Large Scale Data Centers ” will teach you:

  1. How to consider your datacenter like a system for your thermal management strategy
  2. Do you approach cooling a small, medium or large scale datacenter differently or the same?
  3. Are you focusing on the most critical cooling goals for your datacenter or are you chasing the wrong goals and watching heat and power usage spiral?

We’ll answer these questions and more at our free Webinar, “Tools and Techniques for the Thermal Management of Small, Medium and Large Scale Data Centers ”

To join, click to the following link and you can sign up:   Reserve Your Spot at ” “Tools and Techniques for the Thermal Management of Small, Medium and Large Scale Data Centers “

What are Leading Edge Strategies to Cool Laptop Computers and Cramped Computing Spaces? (part 1 of 2)

If you’ve ever kept a laptop computer on your lap for any extended length of time, you know how hot they can get. Cramped computing spaces, such as microTCA, PC104 and custom small form factors can have much the same effect where the chassis is small and close to the components. In the case of laptops, a laptop heat sink with heat pipes abutting a metal chassis can be a solution to transfer the heat from the CPU, chipset and other components. In the case of cramped (or more politely, small form factor computing) heat sinks, larger fans and ducted airflow are some default choices. However, leading edge thermal management developments can provide some unique approaches to cooling these use cases. Our two part article here will cover three in particular.

As integrated circuits (ICs) have to provide increased functionality and computational power through a greater number of transistors in smaller and smaller packages, the removal of the heat dissipated by these electronic chips has become a serious challenge in the design of portable and other space-limited electronics devices. The cooling of these electronic chips in notebook computers is especially challenging due to the notebooks small footprint. Currently, heat pipes, as shown in figure 1 [1], are used to transport the heat from the high power components to a remote heat exchanger. The heat is then dissipated to the air passing through the remote exchanger. However, the heat dissipation using a heat pipe is approaching an asymptotic limit for the size restrictions of a notebook-shape form.

heat sink with heat pipe for a laptop computerFigure 1 – Heat Pipe Cooling in Existing Notebook Computer [1]

Alternative cooling approaches have been investigated to achieve the required dissipation rates, while satisfying the required reliability and cost considerations. These methods are thermoelectrics and refrigeration. Given the small cooling capacity and low efficiency of thermoelectrics, a refrigeration system is the only viable method to further increase the heat dissipation of high power components in notebook computers. Refrigeration cooling allows high heat flux dissipation at low junction temperatures, which will increase microprocessor performance at lower operating temperatures and increase chip reliability. However, refrigeration cooling also increases the size, complexity and cost of the cooling system. The complexity would increase the uncertainties in the system reliability.

Vapor Compression Refrigeration System

A basic vapor-compression refrigeration system consists of four major components: an evaporator, a compressor, a condenser and a throttling device.  Figure 2 [2] shows a schematic of a vapor-compression refrigeration system. The main heat transfer mode of the vapor-compression refrigeration cycle is evaporation/condensation of the refrigerant.

Vapor-Compression Refrigeration System Figure 2 – Vapor-Compression Refrigeration System Schematic [2]

When the refrigerant enters the evaporator, it evaporates due to the low pressure and absorbs heat from the evaporator at a constant temperature. Then, the vapor refrigerant travels through the compressor, which increases the pressure of the refrigerant. After the compressor, the vapor refrigerant condenses in the condenser due to the high pressure and rejects heat to the condenser at constant temperature. The refrigerant then travels through a throttling device, which reduces the liquid refrigerant pressure. The low pressure liquid refrigerant re-enters the evaporator and restarts the cycle. Figure 3 [2] shows the thermodynamic state point diagram of a vapor compression cycle.

Figure 3 - Vapor Compression Cycle Thermodynamic State Point Diagram [2]

Figure 3 – Vapor Compression Cycle Thermodynamic State Point Diagram [2]

For electronic cooling, the evaporator would be directly attached to the high power electronic chip, absorbing the chips heat dissipation. The heat dissipation would be rejected to the ambient environment through the air-cooled condenser. Figure 4 [3] shows the schematic of the vapor-compression cycle within a computer.

Schematic of a Miniature Refrigeration SystemFigure 4 – Schematic of a Miniature Refrigeration System [3]

Recently, there have been a lot of studies that aim to further investigate the feasibility of the refrigeration system for electronics cooling. Studies of vapor compression systems and system simulation were directed at electronics cooling in laptop computers. One such study was conducted by Mongia, Masahiro, and DiStefano. The small-scale refrigeration system, within the study, included a compressor, cold plate, condenser and throttling device. These components were specially designed, such that the entire cooling system can be incorporated within a notebook form factor. Figure 5 [2] shows the schematic of the entire system with temperature and pressure measurement points.

Small Scale Refrigeration System Schematic

Figure 5 – Small Scale Refrigeration System Schematic [2]

Iso-butane was chosen as the working fluid. The cold plate and condenser contain microchannels to efficiently transfer heat to and from the refrigerant.  Prototypes of each of the components were built and tested in order to assess their individual performance. Figure 6 [2] shows a complete form factor loop that was also built and tested to determine the system feasibility and overall performance. The test results, as shown in Figure 7 [2], show that this system can achieve a coefficient of performance (COP) > 2.25 at a moderate temperature rise. The thermal resistance of this system ranges from 0.28 – 0.7 °C/W. Figure 8 [2] shows the cooling loop within a notebook.

 photo of Small Scale Refrigeration Form Factor Figure 6 – Complete Small Scale Refrigeration Form Factor Loop[2]

Results from Small Scale Refrigeration Study

Figure 7 – Results from Small Scale Refrigeration [2]

Small Scale Refrigeration System within a Notebook

In part two we’ll cover Miniature Scale Diaphragm Compressors and Micro-Channel Heat Sinks.

Reference:

1. Review Core Duo vs. Core 2 Duo, NotebookCheck website http://www.notebookcheck.net/Review-Core-Duo-vs-Core-2-Duo.2404.0.html

2. Mongia R. et al., Small Scale Refrigeration System for Electronics Cooling within a Notebook Computer, Proceedings SEMITHERM XXII, March 2006, San Clara, pp.751-758

3. Miniature Refrigeration System for Electronics Cooling, Minicool website http://www.minicool.co.uk/project.html

4. CTRC Breakthroughs, CTRC website https://engineering.purdue.edu/CTRC/research/breakthroughs.php

5. Purdue Miniature Cooling Device Will Have Military, Computer Uses, ScienceDaily website http://www.sciencedaily.com/releases/2005/04/050414173948.htm

6. Miniature Cooling Device, California Science & Technology News website http://www.ccnmag.com/article/miniature_cooling_device

7. Trutassanawin S. et al., “Experimental Investigation of a Miniature-Scale Refrigeration System for Electronics Cooling”, CTRC Research Publications, Sept. 2006, pp.678-687.

8. Chiriac V., Chiriac F., “Optimized Refrigeration Vapor Compression System for Power Microelectronics Cooling”, Proceedings of Clima 2007 WellBeing Indoors.

Selecting a Fan for Your Thermal Management System (part 2 of 2)

In part 1 of our 2 part series this week, “Selecting a Fan for Your Thermal Management System”, we talked about how the type of fan needs to be chosen based on chassis design and allowable space. We discussed a bit about fan types and how to estimate the amount of airflow a system needs. Today in part 2, we’ll talk about fan impendance curves, pressure drop, and the effect of multiple fans.

For high heat loads, with concentrated heat sources you must design to the worst case component. Spot cooling may be accomplished with internal fans, heatsinks, ducting etc.

Next the total system impedance curve is needed, or the very least, the system pressure drop at the desired flow rate. System resistance is defined as:

System Pressure Drop

Where:
System Resistance Calculations

For practical purposes the value of can only be found experimentally or using computational fluid dynamics. Due to the complex nature of modern electronics enclosures an accurate value of cannot be derived analytically. In a modern electronics enclosure the airflow is turbulent and the value of can be conservatively chosen as 2.

Typical Fan ImpedanceTypical Fan and Impedance Curves (3)

The calculated flowrate at a specific static pressure can then be compared to a specific fan curve to determine if the fan will be adequate. An example fan curve is shown in figure 5. Point A is known as the “no flow” point of the fan curve, where the fan is producing the highest pressure possible. Next is the stall region of the fan, B, which is an instable operating region and should be avoided. The area from point C to D is the low pressure region of the fan curve; this is a stable region of fan operation and should be the design goal. It is best to select a fan that operates to the higher flow area of this region to improve fan efficiency and compensate for filter clogging.

In many systems a single fan cannot deliver the entire volumetric flow rate needed. In these situations multiple fans can be used, either in parallel or series configurations. In order to determine which configuration is more appropriate the system impedance curve is once again needed (figure 6). For a high impedance system two fans in series will produce a higher flow rate than in parallel. The opposite behavior can be expected in a low impedance system, where parallel fans are preferred.

Effect of Multiple Fans on Air Flow in a System

Figure 6. Effect of multiple fans on system pressure and flow rate [Comair Rotron]

An important consideration that needs to be addressed once the fan has been selected is to configure them in a blow through or pull through configuration. The airflow into a fan can roughly be modeled as laminar, whereas the exit airflow is highly turbulent. This phenomenon can be useful in thermal management, for instance in a typical telecom sub rack. Due to the varied resistance that the PCBs impose and the close proximity of the fans (fan tray) to the cards, the laminar flow will assist in better velocity distribution in the sub-rack, which also functions as a plenum.

In the blow through configuration the turbulent air has a positive effect on the heat transfer coefficient which can be useful when dealing with concentrated heat sources. The blow through design allows the fan to push cooler air, which improves its pressure capability, and extends the life of the fan. In this configuration the enclosure is slightly pressurized which prevents unfiltered air from being drawn through the joints and gaps in the chassis.

References:

Common Fan Laws

1. Fan Cooled Enclosure Analysis Using a First Order Method, Ellison, Gordon, N., Electronics Cooling, Vol. 1, No. 2, October 1995, pp. 16-19.

2. Practical Guide to Fan Engineering, Daly, Woods, Woods of Colchester, Ltd, 1992

3. All you need to know about fans, Mike Turner, Electronics Cooling, Vol.1 May 1996

4. Comair Rotron, Establishing Cooling Requirements: Air Flow vs. Pressure, www.comairrotron.com/airflow_noe.shtml, March 12, 2007