Category Archives: Heat Sinks

How to Apply Natural Convection Cooling for the Thermal Management of Electronics (part 2 of 3)

In part 1 of our 3 part series, we covered why and how natural convection works and how a heat sources geometry can affect natural convection. Today, in part 2, we want to address board orientation and its impact on natural convection cooling and useful equations that can be used for calculating initial and simplistic results based on viable assumptions.

For maximum heat transfer in applications where the desired cooling method is natural convection, boards with power dissipating devices should be stacked in the vertical plane. Packing boards in the vertical direction increases the spatial consolidation of the boards and increases heat transfer per unit area due to optimized natural convection.

For a single plate suspended in the vertical configuration, the resulting velocity profile will be parabolic. There is no interference with any other disturbances; the only controllable variables are adjusting the height, width and power of the board. When multiple boards are stacked to create vertical channels, the velocity profiles interact. Their interaction is a function of the spacing, or channel width, between the boards. Figure 2 is an adapted graph showing the heat dissipation of a set of two parallel isothermal plates as a function of channel width at a temperature difference of 20°C and a constant board area of 0.078m2. A and B are design points where the slope of the line connecting to the origin represents the amount of power per unit of channel width. Point B is shown to have a maximum slope, which represents the maximum possible packing density for a particular configuration. In order to maximize power density for isothermal boards, an engineer should aim to design for point B. Note that past the optimum and toward point A there is no longer any potential gain in power consumption as the channels are widened.

Heat Dissipation from Isothermal Boards as a Function of Board Spacing in Natural Convection

Figure 2. Heat Dissipation from Isothermal Boards as a Function of Board Spacing in Natural Convection [2].

The relationship discerning board optimization for isothermal boards can be described [2] as:

The mathematical relationship discerning board optimization for isothermal boards

Where:

S(opt) = optimal board spacing

H  = board height

[delta]T = temperature difference (degree C) for a 50 degree C Ambient

For the configuration of two isothermal plates, the average Nusselt number across a plate can be described by the following equation [3]:

For the configuration of two isothermal plates, the average Nusselt number across a plate can be described by this formula

where :

R(a) = the Rayleigh number – a non-dimensional number associated with the magnitude of buoyancy flow

H(b) = board height (m)

S(b)  = board surface area (m2)

For a channel between two plates with equal heat flux, the hottest — and thus the most critical point of interest — rests at the end of the board nearest the exhaust of the channel. In this particular configuration, the optimal spacing can be defined as [3]:

Formula for the optimal spacing for a channel between two plates

Where:

Ra(s) = the Rayleigh number

S =  board spacing (m)

H =  board height

Likewise, a calculation for the local heat transfer coefficient at the end of a set of plates with uniform heat flux can be found as [3]:

calculation for the local heat transfer coefficient at the end of a set of plates with uniform heat flux

where:

q”(s) = heat flux generation

T(s) = surface temperature at board edge

T(a)  =  ambient air temperature

S  = board spacing

K(f)  =  thermal conductivity of the fluid

The above equations are useful for calculating initial and simplistic results based on viable assumptions. A stack of boards can often be modeled as plates where there are less significant heat source points or protrusions from the board, or where the thermal conductivity of the board is high enough to assume isothermal characteristics. For some cases, memory modules aligned in channel-like configurations can be modeled as a set of plates with uniform heat flux – the heat transfer characteristics can be estimated from the above correlations. Similarly, the fins of a heat sink in natural convection can be modeled as isothermal plates which create channels. For most heat sinks, their material conductivity is high enough to negate any significant temperature gradients along the fins.

In part 3 we’ll cover the calculations in generic plate fin heat sinks, and conclude our 3 part series on How to Apply Natural Convection Cooling for the Thermal Management of Electronics.

References

2. Malhammar, A., Optimum Sized Air Channels for Natural Convection Cooling, Telecommunications Energy Conference, 1987.

3. Incropera, F., Liquid Cooling of Electronic Devices by Single Phase Convection. New York, Wiley. 1999.

How to Apply Natural Convection Cooling for the Thermal Management of Electronics (part 1 of 3)

Today we are going to start a three part series here at ATS’s blog to discuss natural convection cooling and how to apply it to the thermal management of electronics. Click here for part 2 and here for part 3.

Most high-powered electronic devices are cooled by forced convection airflow, but occasionally there is a need for natural convection cooling. Determining factors, which include cost, noise, vibration and reliability, can eliminate use of a fan or blower  particularly in consumer electronics and outdoor enclosures. Fan failure will also change the flow regime from forced flow to natural convection.  In contrast with airflow generated by the mechanical workings of a prime air mover, natural convection results from the buoyancy forces generated by the ambient air being heated by a heat source. Air adjacent to the heat source absorbs heat from the surface, becomes hotter than the surrounding air, and rises due to density differences. Cooler air displaces the warmer air and a natural convection flow thus develops. The magnitude of the airflow depends on the solid geometry, surface heat flux and the buoyancy characteristics of the carrying fluid as determined by the dimensionless Rayleigh number.

The geometry of a heat source plays an important role in determining heat transfer characteristics. Consider a power consuming chip on a circuit board: the orientation of the board relative to the direction of gravity can have a large effect on cooling the chip via natural convection. An adapted form of Ellisons[1] model can be used for simplified configurations, as shown below in Figure 1, to predict the local heat transfer coefficient for a specific heat source per a specific orientation relative to the direction of gravity.

Formula to to predict the local heat transfer coefficient for a specific heat source per a specific orientation relative to the direction of gravity

Where:

h  = the heat transfer coefficient from the surface (W/m2.°C)

T(w) = the package surface temperature (°C)

T(a) = the ambient flow temperature (°C)

f, n = constants listed in Table 1

L(ch) = the characteristic length (meters) as defined in Table 1

Figure 1.  Common Orientations of Electronics Boards
Circuit Board Examples for Convection Cooling

Figure 1 presents two common configurations of electronics boards. Example A is a set of PCI express cards which are stacked along the vector of gravity, so that the boards are perpendicular to gravity. Example B shows a stack of ATCA boards which aligned parallel to gravity.

Table 1. Table of Parameters Used in Ellison’s Analytical Model [1]

Table 1. Table of Parameters Used in Ellison’s Analytical Model

In part 2 we’ll cover board orientation and its impact on natural convection cooling and useful equations that can be used for calculating initial and simplistic results based on viable assumptions.

—————————

References
1. Hwang, P., Cheng, H., Fang, J. and Li, J., CFD-Based Thermal Characterization of Board-Level Microelectronic Devices under Natural Convection Cooling, Microsystems, Packaging, Assembly and Circuits Technology, 2007. IMPACT 2007.

ATS Thermal Labs White Paper: How to calculate heat sink thermal resistance in order to choose the best one for your thermal management solution

Heat Sinks are disarmingly simple.  Extruded, stamped or forged, aluminum or copper, heat sinks are vital to the best operation of our hot computing systems. Most times, the choice of the best heat sink solution is a matter of considering only its total device power dissipation. While a heatsink may appear structurally simple, the fluid flow through its fin field and thermal coupling with its surrounding create a more complex problem. Actually, the most important characteristic of a heat sink is its thermal resistance value.

Our free White Paper, “Heat Sink Thermal Resistance Changes with Length and Width” will give our readers all the necessary tools to calculate a heat sink’s thermal resistance value so you can make the best choice.

Vapor Chambers for Thermal Management: A Primer by Thermacore

Thermacore Vapor Chamber Heat Sink Thermacore’s Matt Connors has written up a nice primer on Vapor Chamber technology that’s well worth a read over at Design World Magazine. Among the points he notes:

  • Surface area alone is not enough with highly concentrated heat sources such as high-power electronic components. As the electronic components get smaller and the heat sinks base area increases, a large thermal heat spreading penalty is typically found in the base of the heat sink [ATS: meaning? you can only make a heat sink so big before it doesn’t work efficiently with concentrated heat sources]
  • To stay within the existing heat sink form factor and to reduce the thermal resistance of the larger base, the heat sink’s standard metallic base needs to be replaced with a conducting material. A vapor chamber can be used as the medium to spread heat in the base more efficiently.
  • Vapor chambers are essentially flat or planar heat pipes that use the principles of evaporation and condensation to produce a very high conductivity thermal plane. Vapor chambers are basically evacuated vessels with an internal wick and a working fluid. The wick helps transport the working fluid back to the evaporator surface without using moving parts. Once the fluid evaporates, it travels to the cooler section of the chamber, condenses in the wick, and the cycle continues.

Matt’s got some other choice words as well and his article is a great primer on this topic for our readers.

As Matt notes, vapor chambers are really flat heat pipes.ATS has some resources that can provide you some breadth of information to go with Thermacore’s primer, here’s three ATS Technical White Papers, all for free:

Thermal Management for Testing High-Power IC Devices

AT ATS we come across a wide variety of thermal issues in electronics. One of the more unique problems involved inventing a cooling test head for semiconductor test equipment.The original test head was unable to accurately perform a test since the semiconductors it was testing were so hot!

It appears ATS isn’t the only one running into such  unique problems!

Jihad Hammoud, Ph.D., at Kulicke & Soffa, has written a good article for Evaluation Engineering Magazine entitled, “Thermal Management for Testing High-Power IC Devices“. In his article he notes the following:

  • As the transistor density and switching speed of integrated circuits (ICs) increase and the package size decreases, the emerging generation of high-power ICs requires thermal management during testing to ensure accurate results.
  • The choice of a thermal management system depends largely on the specific test application. High power simulation, temperature characterization, and high-volume production testing are three applications that require thermal management for high power devices. However, each application has different degrees of accuracy, speed, and overall cost.
  • The variations in accuracy, range, speed, and cost of different thermal management methods mean that no single one will meet the objectives of every high-power test application. Rather, the method selected will be the one that best meets the critical requirements of a specific test application.

He has a terrific chart at the end that does a nice job of summarizing various thermal management options. The article is well worth a read on the topic of thermal management in test.  You can find it at Evaluation Engineering Magazine, “Thermal Management for Testing High-Power IC Devices“.