Free, Quick, One Page List of Our Best Practice Using CFD

As part of our webinar today, we’ll be talking about some best practices we use at ATS when we perform CFD. We thought we’d share the list here with our readers and followers:

  1. Get a full understanding of the software’s capabilities before launching analysis
  2. Understand and develop accurate boundary conditions
  3. Perform analytical analysis before starting CFD simulations
  4. Brute force complete modeling is only a sign of a neophyte always look for the lines of symmetry to see how you can reduce your model size
  5. Not doing mesh sensitivity analysis is like committing a cardinal sin. Such analysis is a cornerstone of obtaining accurate answers
  6. Believing your CFD results w/o validation (second independent solution, is like believing in magic. Any analysis, whether done by simulation, analytical or experimental, must be validated

We’ll be Live Tweeting our webinar “CFD Tips and Tricks” today. The hashtag is #ats_cfd

If you haven’t signed up yet, here’s the link: https://www2.gotomeeting.com/register/300959811

Selecting a Fan for Your Thermal Management System (part 2 of 2)

In part 1 of our 2 part series this week, “Selecting a Fan for Your Thermal Management System”, we talked about how the type of fan needs to be chosen based on chassis design and allowable space. We discussed a bit about fan types and how to estimate the amount of airflow a system needs. Today in part 2, we’ll talk about fan impendance curves, pressure drop, and the effect of multiple fans.

For high heat loads, with concentrated heat sources you must design to the worst case component. Spot cooling may be accomplished with internal fans, heatsinks, ducting etc.

Next the total system impedance curve is needed, or the very least, the system pressure drop at the desired flow rate. System resistance is defined as:

System Pressure Drop

Where:
System Resistance Calculations

For practical purposes the value of can only be found experimentally or using computational fluid dynamics. Due to the complex nature of modern electronics enclosures an accurate value of cannot be derived analytically. In a modern electronics enclosure the airflow is turbulent and the value of can be conservatively chosen as 2.

Typical Fan ImpedanceTypical Fan and Impedance Curves (3)

The calculated flowrate at a specific static pressure can then be compared to a specific fan curve to determine if the fan will be adequate. An example fan curve is shown in figure 5. Point A is known as the “no flow” point of the fan curve, where the fan is producing the highest pressure possible. Next is the stall region of the fan, B, which is an instable operating region and should be avoided. The area from point C to D is the low pressure region of the fan curve; this is a stable region of fan operation and should be the design goal. It is best to select a fan that operates to the higher flow area of this region to improve fan efficiency and compensate for filter clogging.

In many systems a single fan cannot deliver the entire volumetric flow rate needed. In these situations multiple fans can be used, either in parallel or series configurations. In order to determine which configuration is more appropriate the system impedance curve is once again needed (figure 6). For a high impedance system two fans in series will produce a higher flow rate than in parallel. The opposite behavior can be expected in a low impedance system, where parallel fans are preferred.

Effect of Multiple Fans on Air Flow in a System

Figure 6. Effect of multiple fans on system pressure and flow rate [Comair Rotron]

An important consideration that needs to be addressed once the fan has been selected is to configure them in a blow through or pull through configuration. The airflow into a fan can roughly be modeled as laminar, whereas the exit airflow is highly turbulent. This phenomenon can be useful in thermal management, for instance in a typical telecom sub rack. Due to the varied resistance that the PCBs impose and the close proximity of the fans (fan tray) to the cards, the laminar flow will assist in better velocity distribution in the sub-rack, which also functions as a plenum.

In the blow through configuration the turbulent air has a positive effect on the heat transfer coefficient which can be useful when dealing with concentrated heat sources. The blow through design allows the fan to push cooler air, which improves its pressure capability, and extends the life of the fan. In this configuration the enclosure is slightly pressurized which prevents unfiltered air from being drawn through the joints and gaps in the chassis.

References:

Common Fan Laws

1. Fan Cooled Enclosure Analysis Using a First Order Method, Ellison, Gordon, N., Electronics Cooling, Vol. 1, No. 2, October 1995, pp. 16-19.

2. Practical Guide to Fan Engineering, Daly, Woods, Woods of Colchester, Ltd, 1992

3. All you need to know about fans, Mike Turner, Electronics Cooling, Vol.1 May 1996

4. Comair Rotron, Establishing Cooling Requirements: Air Flow vs. Pressure, www.comairrotron.com/airflow_noe.shtml, March 12, 2007

Selecting a Fan for Your Thermal Management System (part 1 of 2)

Designing a forced convection system for a chassis or cabinet is a complicated task which must be done correctly to ensure the performance and reliability of the enclosed electronics. There are many thermal, mechanical, and electrical effects to consider when selecting a fan.

First the type of fan needs to be selected, based on chassis design and allowable space. The two types are:

Vane-Axial- Air flow is parallel to the fans Axis, high flow rate, and low pressure (figure 1)

Vane Axial FanBlower- Air flow is perpendicular to fan axis, low flow rate, and high pressure (figure 2)

Blower air mover

To select the appropriate fan we need to estimate the necessary airflow needed for a system. For low power, uniform heat loads we can use a simple steady state analysis to balance airflow and temperature rise. The power dissipation of the chassis and desired temperature rise are used in the following equation to obtain a target flow rate.

equations for air movers and fans in chassis

For high heat loads, with concentrated heat sources you must design to the worst case component. Spot cooling may be accomplished with internal fans, heatsinks, ducting etc.

On Wednesday we’ll have the second part of this article, covering the total system impendance curve and more on calculated flow rates.  Click here to right to part 2.

References

common fan laws

Common Fan Laws for Electronic Enclosures

1. Fan Cooled Enclosure Analysis Using a First Order Method, Ellison, Gordon, N., Electronics Cooling, Vol. 1, No. 2, October 1995, pp. 16-19.

2. Practical Guide to Fan Engineering, Daly, Woods, Woods of Colchester, Ltd, 1992

3. All you need to know about fans, Mike Turner, Electronics Cooling, Vol.1 May 1996

4. Comair Rotron, Establishing Cooling Requirements: Air Flow vs. Pressure, www.comairrotron.com/airflow_noe.shtml, March 12, 2007

Why Temperature is Critical in Thermal Management

Last week in this series on How to Select a Heat Sink for an OEM Project, we talked about why thermal management is a challenge to design for. This week we want to talk about why temperature is critical in Thermal Management.

The fact that temperature is critical in thermal management would seem self-evident, but, as with many things in thermal management, there’s more here than meets the eyes.

Power dissipation from electronics is on the rise, and so is its consequence on temperature. As a result, accurate temperature measurement is playing a larger role in the successful launch of new products.

Figure 1 shows a typical flow chart for a products design cycle [1]. Thermal engineering is required in three distinct areas: Concept, Prototype, and Verification.

The Role of Thermal Management in the Product Design Cycle

At the Concept level, thermal analysis is performed to ascertain the design feasibility and move the product to the Prototype stage. Here, the product is assembled and temperature measurements are taken to ensure the design meets the intended specs while there is a level of system functionality. If the design passes this stage, the product is fabricated. Then, the fully-functional system is checked for adherence to its intended design features while it is stressed at elevated temperatures. This is part of the Verification stage.

At all three stages, accurate knowledge of temperature is needed to ensure the system meets expected performance levels. An engineer designing an MRI system certainly wouldn’t want to include non-existing, extra features in the digital image as a result of excess temperature. Nor, by analogy, would someone transferring funds in a bank transaction want their electronics to place extra zeros in the transfer amount because of temperature overshoots in the system.

Equally important is the expected life of an electronics system. Every company wants to ensure that its products will successfully function in their intended environment. And every company wants their products to be first on the market. To support these goals, a fair amount of reliability calculations must be performed.

Continue reading →

Free ATS Webinar: How to Properly Measure Temperature within Electronic Systems and Analyze the Results

On Thursday, April 28, 2011 2:00 PM – 3:00 PM EDT, ATS will be holding a free webinar, “How to Properly Measure Temperature within Electronic Systems and Analyze the Results”

Attendees will become familiar with the importance of temperature measurement in electronic systems. They will learn about the essential instruments and the locations within a system where testing should be conducted.  The webinar presenter will also discuss how to analyze the temperature data as part of a complete thermal analysis.

To register, click to our registration site at this link: https://www2.gotomeeting.com/register/952923650

For the Chinese Mandarin presentation of our webinar please register at http://bit.ly/ATS_temp_mesaurement_Mandarin