Tag Archives: thermal design

Selecting a Fan for Your Thermal Management System (part 2 of 2)

In part 1 of our 2 part series this week, “Selecting a Fan for Your Thermal Management System”, we talked about how the type of fan needs to be chosen based on chassis design and allowable space. We discussed a bit about fan types and how to estimate the amount of airflow a system needs. Today in part 2, we’ll talk about fan impendance curves, pressure drop, and the effect of multiple fans.

For high heat loads, with concentrated heat sources you must design to the worst case component. Spot cooling may be accomplished with internal fans, heatsinks, ducting etc.

Next the total system impedance curve is needed, or the very least, the system pressure drop at the desired flow rate. System resistance is defined as:

System Pressure Drop

Where:
System Resistance Calculations

For practical purposes the value of can only be found experimentally or using computational fluid dynamics. Due to the complex nature of modern electronics enclosures an accurate value of cannot be derived analytically. In a modern electronics enclosure the airflow is turbulent and the value of can be conservatively chosen as 2.

Typical Fan ImpedanceTypical Fan and Impedance Curves (3)

The calculated flowrate at a specific static pressure can then be compared to a specific fan curve to determine if the fan will be adequate. An example fan curve is shown in figure 5. Point A is known as the “no flow” point of the fan curve, where the fan is producing the highest pressure possible. Next is the stall region of the fan, B, which is an instable operating region and should be avoided. The area from point C to D is the low pressure region of the fan curve; this is a stable region of fan operation and should be the design goal. It is best to select a fan that operates to the higher flow area of this region to improve fan efficiency and compensate for filter clogging.

In many systems a single fan cannot deliver the entire volumetric flow rate needed. In these situations multiple fans can be used, either in parallel or series configurations. In order to determine which configuration is more appropriate the system impedance curve is once again needed (figure 6). For a high impedance system two fans in series will produce a higher flow rate than in parallel. The opposite behavior can be expected in a low impedance system, where parallel fans are preferred.

Effect of Multiple Fans on Air Flow in a System

Figure 6. Effect of multiple fans on system pressure and flow rate [Comair Rotron]

An important consideration that needs to be addressed once the fan has been selected is to configure them in a blow through or pull through configuration. The airflow into a fan can roughly be modeled as laminar, whereas the exit airflow is highly turbulent. This phenomenon can be useful in thermal management, for instance in a typical telecom sub rack. Due to the varied resistance that the PCBs impose and the close proximity of the fans (fan tray) to the cards, the laminar flow will assist in better velocity distribution in the sub-rack, which also functions as a plenum.

In the blow through configuration the turbulent air has a positive effect on the heat transfer coefficient which can be useful when dealing with concentrated heat sources. The blow through design allows the fan to push cooler air, which improves its pressure capability, and extends the life of the fan. In this configuration the enclosure is slightly pressurized which prevents unfiltered air from being drawn through the joints and gaps in the chassis.

References:

Common Fan Laws

1. Fan Cooled Enclosure Analysis Using a First Order Method, Ellison, Gordon, N., Electronics Cooling, Vol. 1, No. 2, October 1995, pp. 16-19.

2. Practical Guide to Fan Engineering, Daly, Woods, Woods of Colchester, Ltd, 1992

3. All you need to know about fans, Mike Turner, Electronics Cooling, Vol.1 May 1996

4. Comair Rotron, Establishing Cooling Requirements: Air Flow vs. Pressure, www.comairrotron.com/airflow_noe.shtml, March 12, 2007

How to Select a Heat Sink: Why Thermal Management is a Challenge

Today we are kicking off a series of articles on how to select a heat sink for an OEM project. The principles are the same for overclockers building their own systems with one difference. In OEM projects, mechanical engineers usually (but not always) have a chance to simulate the design before hand and suggest changes to chassis and layout to help with airflow.

So, let’s get started with some basics. First, why is thermal management a challenge? There’s a few reasons and many of these are only getting worse if you consider them from the world of thermal engineering.

First on our list is higher frequency circuits. The International Technology Roadmap for Semiconductors notes that, “projected power density and junction-to-ambient thermal resistance for high-performance chips at the 14 nm generation are >100 W/cm2 and <0.2°C/W, respectively.” In other words, semiconductors are simply getting hotter as their clock speeds are increased.

Second, generally, semiconductors are being assembled into smaller packages. The packages are smaller, the circuits are denser and this combination means that they are warmer.

Third on our list of why thermal management is a (growing) challenge is low acoustic noise requirements. End users don’t want to be deaf just for using electronics. The result is many specifications that set a reasonable acoustic range for their equipment, often in the 100LFM to 400LFM range. This relatively low airflow is great for end users but creates a real challenge for mechanical engineers and systems integrators trying to create a solid system that meets end users needs and still operates at its optimal levels.

Fourth, circuit designers determine component placement. On the surface of this, this is how it should be. Electrical engineers have alot of pressure on them to reduce board latency and design for performance. While they often consider the thermal needs of the systems and circuits, it’s not their primary design point. For mechanical engineers that is what we do and so our challenge is the balancing act of working with EE’s to insure great placement, but also great airflow.

Fifth and finally, thermal management is a challenge because EMI shielding. Higher frequency components require better shielding and that shielding can restrict airflow.

When we pick this topic up next, we’ll cover why temperature is so important to manage. If you have any questions in the mean time about heat sinks or thermal management, contact us and lets see how can make your next project a success! Email us at ATS thermal [email protected] , call us at 781-769-2800 or visit our heat sink catalog at qats.com

 

Thermal Coupling in Electronics Cooling (part 2 of 2)

In part 1 we wrote about what thermal coupling is and how the coupling effect works. Here in part 2 we’ll explore the coupling effect of radiation, conduction and convection.

To better understand the coupling effects of radiation, conduction and convection and their relative contributions to heat transfer, a model of the case from part 1 of this 2 part series was constructed and solved in CFD. A picture of the set-up is shown in Figure 2.

View of Tunnel With Test Block for Thermal Coupling ExampleFigure 2. View of Tunnel With Test Block

The CFD analysis was performed for the following four cases:

  1. The test block was assumed to be made of aluminum and radiation boundary conditions were applied (the walls of the tunnel were assumed to be isothermal at a temperature of 5°C.)
  2. The block was assumed to be made of aluminum and no radiation boundary conditions were applied (there was no applied wall temperature or emissivity)
  3. The block was assumed to be made of multilayer PCB material and radiation boundary conditions were applied (the tunnel walls were assumed to be isothermal at a temperature of 5°C.)
  4. The block was assumed to be made of multilayer PCB material and no radiation boundary conditions were applied (no applied wall temperature or emissivity)

Each of the four cases above was solved for air velocities of 0.125, 0.25, 0.5, and 1 m/s. For each case, the maximum temperature at the heat source is shown in Table 1 below.

Temperature Data Obtained from CFD for Thermal Coupling ExperimentGraph of Radiation and Convections Results for CFD
Figure 3: Graph of Radiation and Convection Results for CFD

This graph is especially revealing. First, in all cases, increasing the air flow resulted in greater convective heat transfer and lower max temperatures. Further, as the surface temperature of the block decreased, the radiation heat transfer relative to the convective heat transfer was reduced. This is evidenced by the converging lines for each block material (with radiation on or off). Finally, the effect of conduction can be seen in the offset in temperatures between the aluminum and the layered PCB blocks. The max temperatures for the Al blocks were consistently lower than those for the PCB blocks. This makes sense because Al is a considerably better conductor than PCB material; and thus the source heat traveled more efficiently through the Al to the surface of the block where it was dissipated by convection and radiation. Figures 4 and 5 show the temperature distribution through the different block materials.

Temperature Distribution Through an Aluminum Block
Figure 4: Temperature Distribution Through an Aluminum Block

Temperature Distribution through a PCB Block
Figure 5: Temperature Distribution through a PCB Block

It is important to understand the role of thermal coupling in the cooling of electronic devices. The example above illustrates how the different modes of heat transfer are interrelated.

In general, the convective mode of heat transfer requires a fluid. Its effectiveness is strongly dependent on the convective heat transfer co-efficient, which is a function of the fluid velocity and temperature. Because convection is a dominant mode of heat transfer for many electronics cooling applications, thermal engineers should try to maximize the available air flow in a given situation.

The radiation mode of heat transfer requires no medium. It can occur in a vacuum, such as space. Radiation is dominant when temperature differences are great. As seen in the example above, the effect of radiation heat transfer can be significant and should not be ignored.

Finally, the conductive mode of heat transfer requires a solid. Conduction is dependent on the thermal conductivity of the solid, which is usually assumed to be constant for most materials. Thermal engineers should make use of high conductivity materials whenever possible.

Got a question on part 1 or part 2 from today? Contact us and we’ll clarify. And, lets see how ATS thermal engineers can make your next project a success! Email us at [email protected] , call us at 781-769-2800 or visit our Design Services

References

1. CFdesign® Software, Blue Ridge Numerics, Inc.

Thermal Coupling in Electronics Cooling (part 1 of 2)

Today we begin a two-part series on Thermal Coupling in Electronics Cooling. In part 1 we’ll cover what thermal coupling is and how the coupling effect works.

Thermal coupling is the interrelationship among the three primary modes of heat transfer: conduction, convection and radiation. Each of these modes is common in electronics cooling and thermal engineers must understand how they can be used together to lower the junction temperature of hot electronic components.

To further explore heat transfer types, a simple virtual test was performed using CFdesign software [1]. A block of material was modeled and subjected to a prescribed heat load. The block was cooled via convection (air flow over the block) and radiation heat transfer. Different block materials were modeled to understand how their inherent thermal conductivity affected overall heat transfer. Each of the test cases was plotted on a graph to show the coupling effects of the various modes of heat transfer.

The test featured a 60 mm x 60 mm block of solid material set in a 250 mm x 25 mm tunnel (or duct). A 10 mm x 10 mm heat source was applied to the blocks base. Figure 2 shows a schematic of the thermal resistance network for this case. The schematic, Figure 1, is a one-dimensional representation of the heat transfer path with the convective, radiative and conductive resistances clearly shown.

Network Model for Solid Block with Heat Source

Figure 1. Network Model for a Solid Block with Heat Source

This model shows that heat must first flow through the solid block via conduction. It can then be dissipated to the wall of the tunnel by radiation or carried away in the fluid (air flow) by convection. In effect, the block is thermally coupled to the tunnel walls and to the air passing through the tunnel.

The total convective resistance in the network is equal to the sum of the convective resistances from the surface of the block to the fluid (Rconvcf), and from the fluid to the walls of the tunnel (Rconvfw). It is defined in Equation 1 below.

Rconv = Rconvcf+ Rconvfw (1)

The total conductive resistance is equal to the sum of the through-plane conduction for the block and the spreading resistance or in-plane conduction through the block. This is defined in Equation 2:

Rcond = Rcond + Rsp (2)

The radiation resistance (Rrad) is defined from the surface of the block to the walls of the tunnel.

In part 2 we’ll explore the coupling effect of radiation, conduction and convection.

Got a question on part 2 already or maybe part 1 from today? Contact us and lets see how ATS thermal engineers can make your next project a success!  Email us at [email protected] , call us at 781-769-2800 or visit our Design Services

—————————-
References

1. CFdesign® Software, Blue Ridge Numerics, Inc.

 

Free ATS Webinar: How to Properly Measure Temperature within Electronic Systems and Analyze the Results

On Thursday, April 28, 2011 2:00 PM – 3:00 PM EDT, ATS will be holding a free webinar, “How to Properly Measure Temperature within Electronic Systems and Analyze the Results”

Attendees will become familiar with the importance of temperature measurement in electronic systems. They will learn about the essential instruments and the locations within a system where testing should be conducted.  The webinar presenter will also discuss how to analyze the temperature data as part of a complete thermal analysis.

To register, click to our registration site at this link: https://www2.gotomeeting.com/register/952923650

For the Chinese Mandarin presentation of our webinar please register at http://bit.ly/ATS_temp_mesaurement_Mandarin