The Importance of Heat Flux Sensors

Heat flux sensors are practical measurement tools which are useful for determining the amount of thermal energy passed through a specific area per unit of time. Measuring heat flux can be useful, for example, in determining the amount of heat passed through a wall or through a human body, or the amount of transferred solar or laser radiant energy to a given area.

Affixing a thin heat flux sensor to the top of a component will yield two separate values which are useful in determining the convection heat transfer coefficient. If the heat flux can be measured from the top of the component to the ambient airstream and if the temperature at the top of the component and of the ambient airstream is measured, then the convection coefficient can be calculated.

Where:

q = Heat flux, or transferred heat per unit area

h = Convection coefficient

TS = Temperature at the surface of the solid/fluid boundary

TA= Ambient airstream temperature

Using a heat flux sensor can be useful for lower powered systems under natural convection scenarios. Under forced convection, the heat lost to convection off the top of a component can often be significantly higher than the heat lost to the board, particularly if the board is densely populated and the temperature of the board reaches close to the temperature of the device. Under natural convection situations, often the balance of heat lost to convection and heat lost through the board becomes more even and it therefore is of even greater interest to the designer to understand the quantity of heat dispersed through convection.

Experiments done at Bell Labs alluded to the effect of board density on the heat transfer coefficient. In these experiments, thin film heat flux sensors are affixed to DIP devices which populate a board. The total heat generation of the board is kept constant, so the removal of components from a densely populated board only increases the heat generation per component. The results of this particular experiment highlight an increase in the ratio of heat lost through convection from the surface of the component as board density increases and individual device power decreases.

 Surface Heat Flow vs. Board Density

Qs/Qt = the ratio of total heat flow through device surface to total heat generation

σ = the ratio of total device surface area to total board area

If a board was to be sparsely populated, a greater percentage of heat can be transferred to the board due to larger thermal gradients; however since the overall surface area of the sum of devices decreases, to some extent the heat transfer coefficient must increase to reflect a balance. As the number of components decreases, the power generation increases per component, and the larger resulting temperature gradients in the region around the component yield more convective flow and thus an increase in the heat transfer coefficient. On the other hand, if the board becomes more densely populated, the proportion of heat transferred through the surface, as compared to through the board increases, and the overall increase in heat transferred through the surface yields increased flow and heat transfer at an individual component surface.

The use of a heat flux gauge is an important tool for the electronics designer. In particular, by using a heat flux gauge, it is possible to experimentally determine the heat transfer coefficient at a certain location on the electronics board where it would have had to be simply predicted or estimated previously. Due to the complexity of many electrical systems as well as the irregular nature of many boards, often analytical or CFD methods are not accurate and the best approach is empirical techniques. The use of the heat flux sensor can give results which would be difficult to calculate using analytical or numerical simulations. However, like most other instruments, it is important to use the sensor correctly and carefully to decrease the errors within a system and increase the reliability.

ATS Releases Mobile Heat Sink Design Tool for Android

We’ve just released our FIRST mobile application for Android! Our Heat Sink Design Tool is ready for you to download now from the Android Application store. The application will enable users to design a heat sink on their Android equipped mobile device for cooling of their electronic devices. After the design, the user can select to search available databases to see such a product exists. The app is 1.0M in size and requires Android 1.6 or higher. Get yours now for free by clicking to Heat Sink Design Tool on Android

Use cases include:

  • Consultants: Are you on premise with your client? Once you understand your needs for a heat sink, use our heat sink design tool to get a product fast.
  • Field Engineers: If your in the field, taking notes on what heat sink to use might be impractical. Use our heat sink design application to punch in the parameters for a heat sink and get it done right there.
  • Students: If your in the lab working on your next project, why not use our convenient application on your Android device to get our project that much quicker to completion

You say you use an iPhone? Well, we have an App for that too! Apple iPhone Heat Sink Design App

ATS, Inc. announces “on demand” Webinar for Thermal Engineers: Methodologies for Fan Characterization

ATS, Inc. is announcing a new “on-demand” webinar from our thermal engineering team, “Methodologies for Fan Characterization”. This webinar is ready for download and listening 24 hours day from the ATS web site.

Topics covered include:

  • What are the fan types and points of application?
  • Understanding how fans operate and the effect of bypass flow on their operation
  • Fan selection
  • Fan assemblies and their implementation
  • Use of fan laws for sizing
  • Managing acoustic noise
  • Fan characterization

To take part in this webinar, just click to our site to reach the webinar at: Methodologies for Fan Characterization

Dr. Kaveh Azar Interview on ATS’s New Thermal Engineering Design Service for Verizon’s VZ.TPR.9208

We’ve started a new regular feature here at ATS, “The ATS Product Highlight”. Our readers can glance to the right hand column to see our inaugral highlight, ATS’s Verizon’s Thermal Management Design Services, a complete set of services to assist the OEM in passing Verizon’s new NEBS VZ.TPR.9208 Thermal Management Requirements for Improved Energy Efficiency of Telecommunications Equipment.

We caught up with our CEO, Dr. Kaveh Azar, to ask him a few questions about why ATS decided to start such a service, what services ATS is providing and more. Just click on the Slidecast below for this 4 minute overview on ATS’s new service:

[slideshare id=4041294&doc=atsverizontpr-9208services-100510144512-phpapp01]

Our readers can also checkout our initial announcement at heatsinks.wordpress.com by clicking to our post, “ATS Announces Thermal Design Services to help Telecom Equip OEMs meet Verizon’s VZ.TPR.9208 Thermal Management Req.” and our readers can see a 3 minute interview of Verizon’s Chuck Graff, the author of VZ.TPR.9208, as to why Verizon decided to release this specification by clicking to, “Verizon’s Chuck Graff speech on VZ.TPR.9208 Thermal Management Spec; Pass Verizon’s tests by partnering with ATS“

ATS Announces Thermal Design Services to help Telecom Equip OEMs meet Verizon’s VZ.TPR.9208 Thermal Management Req.

Verizon has announced that on July 1st, 2010, it’s Thermal Management Requirements for Improved Energy Efficiency of Telecommunications Equipment, Verizon Technical Purchasing Requirements VZ-TPR-9208, will come into full effect.

What does this mean for the telecommunications equipment provider? Simply that your equipment must be in compliance with this specification in order to be included in Verizon’s network.

At ATS we know this can be a complex process so we’ve released our newly formed Verizon’s Thermal Management Design Services.

ATS is well acquainted with the entire range of NEBS telecommunications requirements, VZ-TPR-9208 just being the latest.  Dr. Kaveh Azar, ATS’s founder, was the founder and manager of Lucent Technologies’ Thermal Management Center, responsible for developing the next generation of cooling systems. In addition, Dr. Azar authored Lucent’s thermal roadmap and served as the corporate thermal consultant. While at Lucent, he developed a state-of-the-art thermal/fluids laboratory for simulation of components, boards and systems.

That same telecommunications thermal management expertise forms the solid foundation for our Verizon Thermal Design Services.