  1. Heat Sink height, length and width
  2. System Airflow velocity
  3. The air temperature
  4. Power dissipation of the target semiconductor
  5. Desired device temperature
  6. Name, company and email

Just a few short questions and we’ll get  you going with a heat sink good for your application or at a minimum as a starting point for your research.

AND if you click on our Big Green Button to check out our new heat sink request tool we’ll send you a free white paper, “Air/Liquid Cooling”. This paper is filled with valuable information on the integration of air and liquid cooling and how to know when it’s time to make the switch.

 

 

How to Mix Water and Air for Electronics Cooling (part 2 of 2)

In part 1 of our 2 part series on Hybrid Liquid/Air Cooling Systems and how you can use them to cool some of your toughest thermal challenges, we covered the air portion of our system, here in part 2 we’ll consider the liquid portion and how to integrate them.

Unless one is using a natural body of water for coolant, or operating in space, at the end of every cooling solution there is a liquid to air heat exchanger, when the generated heat is transferred.

Typical Liquid Cooling SystemFigure 2. Typical Liquid Cooling System

As shown in Figure 2, a conventional liquid cooling system consists of a cold plate, external plumbing, and a heat exchanger. The advantage of this type of system is to increase flexibility in packaging by allowing remote placement of the heat exchanger. Remote mounting does introduce disadvantages, as the external plumbing increases pressure drop throughout the system, which increases the required pumping power. The piping itself is a potential source of leakage at the plumbed junctions, as is the permeability of the piping system.

To appreciate the importance of spreading resistance, lets assume a high heat flux component generates 500 W/cm2 in a 10 x 10 mm package. The size of the copper heat sink used is 80 x 80 mm, with a base thickness of 5 mm. The spreading resistance alone for this case is 0.140C/W. Even if the thermal resistance of the heat sink is 0 (thermodynamically impossible), the temperature rise of the component above ambient is 700C. Considering an ambient of 500C, the above proposed heat sink will not cool the device adequately to prevent it from failure. The above example shows how important the spreading resistance is, especially in high heat flux applications.

There are many methods for reducing the thermal resistance. Among these methods are:

Use of a high conductivity material as the base plate of the heat sink to reduce thermal resistance. These materials include aluminum (k = 180 W/mK), copper (k = 380 W/mK), and CVD diamond (k = 2000 W/mK).
Using passive, high conductivity devices, like heat pipes, thermosyphons, or vapor chambers
Use of thermoelectric devices whose heat spreader structures consist simply of an electrically conductive heat sink with an applied external electric potential.

This induces a Thomson Effect, and provides heat transfer through the device. Of the above, the vapor chamber has been the most desirable method. Basically, a vapor chamber works like a heat pipe. The heat transfer to the base vaporizes the liquid and reaches the cold section of the chamber. The vapor condenses and returns back to the base with the help of the wick structure. But, even though the spreading resistance of a vapor chamber is theoretically appealing, it has been found that, under certain conditions, a solid copper spreader can have lower thermal spreading resistance [2,3,4].

comparison of solid copper heat sink and vapor chamberFigure 3. Comparison of a Solid Copper Heat Sink and a Vapor Chamber

In order to alleviate spreading resistance issues, Advanced Thermal Solutions, Inc. (ATS) has developed a new technology, the Forced Thermal Spreader, or FTS [5]. A schematic picture of the FTS design is shown in Figure 4.

Structure of Advanced Thermal Solutions Thermal SpreadersFigure 4. Structure of Advanced Thermal Solutions’ Forced Thermal Spreader

The FTS design is a combination of mini- and microchannels.

The heat transfer coefficient in the micro-channels is about 500,000 W/m20C. This high heat transfer coefficient creates a very small resistance between the heat source and the incoming liquid. The heat is then transferred to the bottom of the heat sink with the minifins attached to the top plate. Heat then transfers from the top plate to the ambient through the heat sink. The experimental test set up is shown in figure 5.

An experiment with an FTS was performed using an HFC-100 test equipment developed by ATS. The HFC-100 is a computerized data acquisition system capable of controlling up to 1KW of heat generated on a 1 cm2 simulated chip. This instrument is capable of ramping the heat with specified dwell times. The size of the FTS was 100 x 120 mm. Table 1 shows the experimental data from tests performed at power levels of 100, 200, and 300 W/cm2. The results show that the data is independent of the power. The experiment was conducted several times at each power level to ensure data repeatability.

Forced Thermal Spreader Test Set UpFigure 5. Forced Thermal Spreader Test Setup

Experimental Data  for the Thermal Resistance of the FTSTable 1b: Experimental Data for the Thermal Resistance of the Forced Thermal Spreader

The thermal resistance from the FTS is around 0.1370C/W on average. The water flow rate is set as 1.0~1.2 L/min, and it was observed that increasing the flow rate beyond 0.3 L/min had no noticeable change in temperature. One very noticeable phenomenon is the interfacial resistance. Because the heat source is small, 1 cm2, this resistance value is significant even under best contact conditions. It is expected that this number would be much higher in a real device application. For proof, a second experiment was carried out. In this experiment the heat source was made part of the FTS, which eliminated the spreading resistance.

Table 2 shows the data for this case. The thermal resistance of the FTS is about 0.14 to 0.15oC/W.

 

Experimental Data for the Thermal Resistance of the FTS, With No Interfacial ResistanceTable 2. Experimental Data for the Thermal Resistance of the FTS, With No Interfacial Resistance

The importance of the above numbers shows itself when calculating the spreading resistance. For a 100mm x 120mm base size copper heat sink, and a 10mm x 10mm heat source, the spreading resistance is about 0.12 degree C/W.  To achieve the total resistance of 0.14 degree C/W with a copper heat sink, we need a heat sink resistance of 0.02 degree C/W, which is not feasible using just air. To show this, we can look at the thermal resistance of a heat sink:

thermal resistance of a heat sink

Where Cp is the fluid heat capacitance, h is heat transfer coefficient, and is the mass flow rate. Assuming a heat transfer coefficient of infinity (thermodynamically impossible):

coefficient of infinity

To reach a resistance of 0.02oC/W, a velocity of 25 m/sec is required for a heat sink that is 100 mm wide and 20 mm high. In a typical systems environment, the h value is about 100-200 W/m2oC for very high speed flows. Assuming this heat sink has 65 fins at 1 mm spacing, the convective resistance will be around 0.02oC/W, but with an enormous amount of pressure drop of about 20 kpa (80H2O). This is clearly an impractical situation.

The data presented in this article shows that an effective hybrid system (liquid-assisted air cooling) has enormous capability for high heat flux applications. However the reader should not forget that the interfacial thermal resistance will always exist unless the interface is eliminated by integrating the cooling and the package systems. Equally important is the reliability of the cooling loops, as well as active control of the device functionality should the cooling system fail.

Got a question on part 1 or 2? Contact us and lets see how ATS’ thermal engineers can make your next project a success! Email us at [email protected] , call us at 781-769-2800 or visit our Design Services
References:

1. Soul, C., The Benefits of Liquid Cooling over Air Cooling for Power Electronics, www.icepak.com/prod/icepak/solutions/articles/iceart19.htm
2. Sauciu, I., Chrysler, G., Mahajan, R., Spreading in the Heat Sink Base: Phase Change Systems or Solid Metals?, IEEE Transactionson Components and Packaging Technologies, Vol 23, No.4., 2002.
3. Jeung, S., Quantitative Thermal Performance Evaluation of a Cost-effective Vapor Chamber Heat Sink Containing a Metaletched Microwick Structure for Advanced Microprocessor Cooling, Sensors and Actuators, A: Physical Volume 121, Issue 2, 2005.
4. Wei, J., Cha, A., Copeland, D., Measurement of Vapor Chamber Performance, IEEE SEMI-THERM Symposium, 2003.
5. Xiong, D., Azar, K., Tavossoli, B., Experimental Study on a Hybrid Liquid/Air Cooling System, IEEE, Semiconductor Thermal Measurement
and Management Symposium 2006.

 

Are Your Heat Sinks and Thermal Management Strategy for Your Target Seminconductors Optimized or Deadended?

By virtue of the fact that ATS is a provider of heat sinks and thermal management solutions to electronics, much of work is target at the junction temperature of semiconductors. We work with a lot of suppliers in this space, most recently Intel’s Sandybridge. Which leads me to the reason for addressing this topic.

Are Your Heat Sinks and Thermal Management Strategy for Your Target Seminconductors Optimized or Deadended?

Of all the semiconductor providers works with, ATS has done a great deal of work with Caviuim, TI and Freescale. It’s not that their processors are unusually hot, it’s that these firms recognize that ATS does a great job of optimizing a thermal design. Our case studies show a wide range of applications and successes in this optimization.

With Cavium, ATS is a thermal development partner. We’ve tackled a number of difficult designs with them and with Cavium customer’s whose design elements create very dense, high performance products but in some small and low air flow applications.

ATS has two off-the-shelf stocks solutions for Cavium that can be used as design starting points, The ATS-691-C2-R1 offers up a thermal resistance of .6 C/W at 200 LFM and the ATS-725-C1-R1 offers up a thermal resistance of 2 C/W at 200 LFM.

ATS Webinar Archive On Best Heat Sink Materials

We’ve seen a lot of search activity here at ATS’s Electronics Cooling blog for “best heat sink material”. As our reader’s have seen, we have quite a bit of excellent material on that topic and we have a webinar in our archives you might like as well.

Heat Sink Materials: Choices and Tradeoffs is a presentation on heat sink materials, particularly advanced ones, that our readers should listen to as well.  It’s an informative presentation given by a colleague of Dr. Kaveh Azar’s, Dr. Carl Zweben. You’ll be very glad you listened.

Best of all, the cost is free, and part of ATS’s continued drive to support the thermal engineering community.

But, if our information is not quite enough to help you, contact us and let’s see how ATS thermal engineers can make your next project a success! Email us at [email protected] , call us at 781-769-2800 or visit our Design Services

What is a Heat Pipe and How Does it work in Thermal Management? (part 1 of 2)

Heat Pipes have been called Heat Superconductors! In this two part series we’ll talk about what a heat pipe, how they are made, compare them with heat sinks, and talk about performance in various thermal management applications.

Diagram of a basic heat pipeFigure 1 Schematic View of a Heat Pipe [1]

Heat pipes are transport mechanisms that can carry heat fluxes ranging from 10 W/cm2 to 20 KW/cm2 at a very fast speed. Essentially, they can be considered as heat super conductors. Heat pipes can be used either as a means to transport heat from one location to another, or as a means to isothermalize the temperature distribution.

The first heat pipe was tested at Los Alamos National Laboratory in 1963. Since then, heat pipes have been used in such diverse applications as laptop computers, spacecraft, plastic injection molders, medical devices, and lighting systems. The operation of a heat pipe is described in Figure 1.

A heat pipe has three sections: the evaporator, the adiabatic, and the condenser. The interior of the pipe is covered with a wick, and the pipe is partially filled with a liquid such as water. When the evaporator section (Le) is exposed to a heat source, the liquid inside vaporizes and the pressure in that section increases. The increased pressure causes the vapor to flow at a fast speed toward the condenser section of the heat pipe (Lc). The vapor in the condenser section loses heat to the integral heat sink and is converted back to liquid by the transfer of the latent heat of vaporization to the condenser. The liquid is then pumped back to the evaporator through the wick capillary action. The middle section of the heat pipe (La), the adiabatic portion, has a very small temperature difference.

Chart showing pressure drop distribution in a heat sinkFigure 2 Pressure Drop Distribution in a Heat Pipe [1]

Figure 2 shows the pressure drop distribution inside a heat pipe. In order for the capillary force to drive the vapor, the capillary pressure of the wick should exceed the pressure difference between the vapor and the liquid at the evaporator. The graph also shows that if the heat pipe is operated against the force of gravity, the liquid undergoes a larger pressure drop. The result is less pumping of the wick with reduced heat transfer. The amount of heat transfer decrease depends on the particular heat pipe.

A typical heat pipe is made of the following:

  1. Metallic pipe: The metal can be aluminum, copper or stainless steel. It must be compatible with the working fluid to prevent chemical reactions, such as oxidation.
  2. Working fluid: Several types of fluids have been used to date. These include methane, water, ammonia, and sodium. Choice of fluid also depends on the operating temperature range.
  3. Wick: The wick structure comes in different shapes and materials. Figure 3 shows the profiles of common wick types: axial groove, fine fiber, screen mesh, and sintering. Each wick has its own characteristics. For example, the axial groove has good conductivity, poor flow against gravity, and low thermal resistance.
    Conversely, a sintering wick has excellent flow in the opposite direction of gravity, but has high thermal resistance.

Different Wick Structures in a Heat PipeFigure 3 Different Wick Structures

That ends part 1 and in part 2 we’ll address factors that can limit a heat pipes effectiveness, differences in the thermal performance of various heat pipe types, and the spreading resistance of different materials.

Have you got a question on heat pipes or their application? How about an interest in bringing ATS’s team of experienced thermal engineers into one of your projects? You can reach us by visiting http://www.qats.com Purchase heat sinks through our Heat Sink eShop or email us at [email protected] or give us a call at 781-769-2800

References:
1. Faghri, A. Heat Pipe Science and Technology Taylor & Francis, 1995.
2. Thermacore Internation, Inc., www.thermacore.com.
3. Xiong, D., Azar, K., Tavossoli, B., Experimental Study on a Hybrid