How System Flow Affects Fan Sink Performance

Cooling fans consist of an aggregate of airfoils, i.e. blades, positioned around a hub that is driven by an electric motor. Due to their airfoil nature, a pressure differential is required across the blades to create the required flow. Therefore, if this pressure differential is disturbed, fan will suffer performance degradation.

Because air cooling is the most desired method for the thermal management of electronics equipment, fans are used extensively. Applications range from a simple projector to a sophisticated computer. The use of fans in such fluid dynamically complex geometries must be well understood. Equally important is the interaction of the fan with its environment, which will determine its effectiveness as an air mover.

There is much that impacts fan performance. The list includes entrance and exit geometries, size and location of the plenum, its placement in the system, effects of swirl in the air flow, altitude, etc. One area that is not accurately studied, and is continually faced in electronics systems, is the effect of parallel flow over the fan hub.

As mentioned, fans are formed from a series of airfoils. A flow going over the fan hub may impact the pressure differential across the blade that is necessary for the fan to operate properly. This article reports the results of an  experimental investigation for a fan sink that is commonly used in electronics such as PCs and servers.

Fan sinks are commonly used in electronics systems to deliver direct air to devices that need additional cooling. Fans are pressure driven devices, and peripheral flow around them, specifically over the fan blades, may impact their performance. To determine the effect of such system by-pass flow over a fan hub, we considered the fan sink shown in Figure 1. This fan sink is used for cooling a microprocessor and its integral power supply. Our objectives were to determine the air flow of the fan sink, with and without the power supply (blockage), and to evaluate the effect of main stream flow on the fan sink’s performance.

Experimental Procedure

The fan sink was set up in a research-standard wind tunnel allowing the main stream air flow to course over the hub of the fan. This is similar to a typical 1U chassis, where system fans move the air from the rear to the front and the CPU is directly cooled by a dedicated fan sink. A high performance hot wire anemometer (HWA)was used for mapping the flow field in the exhaust of the heat sink. This was done with and without the presence of the CPUs integral power supply. The locations of the velocity probe are shown in Figures 2, 3, and 4.

Positions 0, 1, and 2 (Figure 2) are normal to the planar area of the fan sink, and A, B, C, and D (Figure 3) are along the exhaust area of the unit. Positions A and D were set at the first and last opening of the heat sink, and B and C were 1/3 and 2/3 the distance from the edge, respectively. For all tests, the velocity probe was placed at the halfway point between the heat sink exhaust and the edges of the heat sink, as shown in Figures 2 and 4. This corresponds to positions 0, 1, and 2 in Figure 2 and position 2 in Figure 4. This configuration enabled us to map out the velocity profile in the exhaust of the fan sink at 12 different locations, four positions from left to right (A-D) and three positions top-to-bottom (0-2).

The fan was powered at the nominal 5 volts, consistent with the actual application. The parallel flow was set at four conditions. The first was no flow (V = 0), which established the reference point for this study. Then, the wind tunnel was set at V= 0.5, 1.5, and 3 m/s (100, 300, and 600 ft/min), while measuring at 15 cm upstream of the fan sink assembly. The fan sink was positioned where 0.5 to 3 m/s of flow would pass by its hub while it operated at its nominal condition. Because a fan is a pressure-driven device, it was expected that the flow bypass would adversely impact its performance. At every point of observation, the velocity was measured for two minutes at the rate of two samples per second, resulting in an uncertainty level of + 0.9%.

Results

Table 1 shows the averaged data for velocity and mass flow rate, with and without the power supply in place. The effect of the bypass flow on the fan sinks performance was quantified by comparing the mass flow rates at different velocities. Depending on the magnitude of the system velocity, (i.e. parallel flow) the data shows that the mass flow rate required for cooling the device can be reduced by more than 60.4%.

Figure 5 shows the raw velocity data for all positions measured. Figure 6 shows the velocity data at vertical position 2 and the 4 horizontal positions for the blocked and unblocked cases. It is noteworthy that in both cases the exhaust flow is highly non-uniform. The mass flow rate was calculated based on the open cross-sectional area of the fan sink assembly. The area for the unit with and without the power supply was 0.32×10-3 m2 and 0.13×10-3 m2, respectively.

Observations

The following observations were made as the result of this experimental investigation:

-The fan sink exhibits uneven flow across its exhaust where the power supply resides, as seen in Figures 5 and 6. This may adversely impact the thermal performance of the power supply, depending on its power distribution.

-The uneven flow distribution was observed for both cases (with or without the power supply). Hence, it is attributed to the design of the fan sink rather than the system flow condition alone. For this reason, it is prudent to characterize any fan sink before its implementation in the system.

-Because of the uneven flow distribution, the layout of the component power supply must be carefully considered. The available mass flow rate for cooling is approximately 0.25×10-3 kg/sec.

-The increase in velocity (approximately 20% to 100%) when the power supply is placed in the exhaust of the fan sink is attributed to area reduction.

The mass flow rate is the true measure of available coolant for the power supply, not the air velocity alone. Any obstruction in the intake or exhaust of the fan, e.g. neighboring components in the board layout, must be carefully considered as their presence will impact the performance of the fan sink.

-The flow bypass adversely impacts the performance of the fan sink. The data show 0% reduction in air velocity when the bypass flow is 3 m/sec (with the power supply in place). Additional clogging of the fan sink from dust and other debris will further diminish its performance.

The adverse effect of system flow bypass on the fan sink suggests that system implementation of the fan sink should be carefully considered at the board and system levels. At the very least, the selection (for size) and position of the adjacent components should be carefully considered because the measurement shows that any near vicinity obstacle has a direct impact on the fan’s performance. As we design fan trays with sufficient plenum for the fan to freely exhaust, board level implementation of the fan sink requires similar consideration.

Although detailed flow measurements were taken to characterize the fan sink, the result may not explicitly determine the thermal performance of the power supply and microprocessor. The non-uniformity of the exhaust air from the fan sink suggests that, depending on the heat sink material and the devices power concentration, the heat sink base temperature may be highly non-isothermal. Because fan sinks are used for direct cooling of certain devices, this non-uniformity may adversely impact the thermal management of the device.  The combination of spreading resistance between the fan sink and the device, and the non-uniformity of the exhaust air and the system bypass flow on the fans performance, may render the fan sink inadequate for a given cooling application.

The data suggests that although fan sinks are attractive cooling options, their implementation in a system environment may be more complicated and requires additional investigation. Simply placing a fan sink on top of a hot device may not provide the desired cooling that the engineer envisioned. Therefore, it is strongly recommended not only to carefully quantify system flow bypass on the fan sink, but to also make the proximity of components neighboring the fan sink a point of consideration in the design cycle.

“Heat Sink Selection Made Easy” Free Technical Webinar on June 13

PCB from Tellabs- smaller sige

 

Advanced Thermal Solutions, Inc. (ATS) will present Heat Sink Selection Made Easy, a free technical webinar for engineers involved in the thermal management of electronic components. The hour-long webinar begins at 2:00 ET on Thursday, June 13.

The heat dissipation needs of todays components are more challenging than ever. Choosing the right heat sink the first time is essential. With so many application requirements and heat sink options, this can be a daunting task, but it is made easier by having an informed approach.

In this webinar, attendees will learn the importance of system airflow and its impact on heat sink design; attachment methods and how to solve thermal and mechanical design challenges; and how to make the right off-the-shelf or custom heat sink choice for your application and budget.

Presenting Heat Sink Selection Made Easy is Dr. Kaveh Azar, president, CEO and founder of Advanced Thermal Solutions. Dr. Azar is an active participant in the electronics thermal community and has served as the organizer, general chair and the keynote speaker at national and international conferences sponsored by ASME, IEEE and AIAA.

How to View the June 13th Webinar:

  • The webinar starts at 2PM ET and will be available for 24 hours, until 2PM ET Friday the 14th.
  • ATS felt that this approach would help engineers in other time zones to be able to watch the webinar.

How to Ask Questions?

  • Today’s webinar speaker, Dr. Kaveh Azar, is happy to take your questions via email.
  • Please send email to [email protected] and write in the email’s subject, “Heat Sink Selection Webinar Question”

 

 

 

Increased Performance from High Aspect Ratio Heat Sinks

High Aspect Ratio Heat Sinks from ATSA heat sink’s aspect ratio is basically the comparison of its fin height to the distance between its fins. In typical heat sinks the aspect ratio is between 3:1 and 5:1. A high aspect ratio heat sink has taller fins with a smaller distance between them for a ratio that can be 8:1 to 16:1 or greater.

Thus, a high aspect ratio heat sink provides greater density of fins in a given footprint than a more common sink, and/or stands taller than its conventional counterpart. The great benefit from a high aspect ratio heat sink is the increased amount of heat dissipating surfaces it provides due to its additional fins. Further, these heat sinks do not occupy any more length or width. The result is a more efficient heat sink with higher performance per gram in the same footprint.

Many common heat sinks are unable to serve the needs of high volume applications, due to the fact that their cooling capacity – measured in part by the aspect ratio – is simply not great enough. By nearly doubling a heat sink’s aspect ratio the cooling performance is optimized and heat issues resolved without the need for more complex solutions.

Because high aspect ratio heat sinks are manufactured in similar fashion as conventional heat sinks, their cost is not significantly higher. They can be extruded or bonded. Fins can be straight or folded. For omnidirectional purposes a high density of pins can be used as heat spreaders in place of fins.

High aspect ratio heat sinks are often ideal thermal solutions for workstation CPUs, high performance power supplies and converters, and high-end amplifiers.

Of critical importance when using high aspect ratio heat sinks is providing sufficient airflow to carry away the radiating heat. Passive cooling, e.g. conduction and radiation may be inadequate. Convective heat transfer removes essentially all of the energy from a heat sink under forced air cooling. Particularly with dense fin fields, an improperly directed fan may create stagnation points and high pressure loss. Thermal modeling is recommended when determining the needed active cooling resources.

New maxiFLOW DC-DC Brick Heat Sinks Ideal for Military-COTS Applications

ATS has recently launched a new product line of maxiFLOW heat sinks, specially designed to cool DC-DC converters. The new line of heat sinks can be used with Vicor’s DC-DC converter Bricks, including their military-COTS applications.

 

Vicor’s Maxi, Mini, and Micro series DC-DC converters are relied upon by over eight thousand OEMs for their proven performance, broad coverage of input and output voltages, ease of mechanical mounting and thermal management flexibility. These converter modules use advanced power processing, control, and packaging technologies to provide the performance, flexibility, and ruggedness expected in a Military COTS product. High frequency ZCS/ZVS switching, advanced power semiconductor packaging, and thermal management provide high-power density with low noise and high efficiency.

maxiFLOW Heat Sink for Half Brick DC-DC Converters

 

ATS’ patented maxiFLOW technology cools millions of BGAs and other PCB components. The same technology is now available for cooling eighth, quarter, half and full brick modules, such as the Micro, Mini, and Maxi series from Vicor. Unlike other converter heat sinks, the patented maxiFLOW heat sink design reduces air pressure drop and provides greater surface area, increasing thermal performance by 30-200%.

Vicor’s Micro, Mini, and Maxi DC-DC Converters

Vicor’s offering of full, half, and quarter-brick modules feature a patented low noise design with the highest reliability and power density available. Fully encapsulated, Maxi, Mini and Micro series DC-DC converters utilize a proprietary spin fill process that assures complete, void free encapsulation making them suitable for the harshest environments. Two grades (H & M) are available with temperatures to -55°C operating and -65°C storage. H & M-Grade modules are qualified to the stringent environmental tests of MIL-STD-810 and MIL-STD-202 and undergo 100% Environment Stress Screening.

By combining technology from industry leaders Vicor and ATS, it can be ensured that DC-DC converters will have superior performance in the harshest environments, which is vital for military and aerospace applications.

To learn more about maxiFLOW Brick DC-DC converter heat sinks, please visit our Power Brick Heat Sink Page or email [email protected], or call us 781-769-2800.

Announcing our ATS Electronics Cooling Webinars for Third Quarter of 2012

ATS, Advanced Thermal Solutions, Inc. will present technical webinars on electronic cooling topics in July, August and September 2012. Each of these free events will provide engineering-level training in a key area of modern thermal management.

Here are the different webinar topics and presentation times:

Using Thermal Interface Materials to Improve Heat Sink Thermal Performance

July 26, 2012 at 2:00 p.m. ET

To cool hotter components, engineers are using larger fans and heat sinks, and increasing surface areas. These hardware enhancements can add significantly to design costs. In many cases, cooling performance can be improved by using a higher performance interface material between the case and the heat sink. Participants will learn the importance of lowering thermal resistance using thermal interface materials, or TIMs, and the different kinds of TIMs available from the market.

Air Jet Impingement Cooling

August 23, 2012 at 2:00 p.m. ET

Ongoing increases in power in devices such as processors and IGBTs mean that higher capacity cooling methods are needed to remove excess heat. One such method is the jet impingement of a liquid or gas onto a surface on a continuous basis. Lab experiments at ATS have shown up to a 40% improvement in cooling achieved using this method. This webinar will explore jet impingement cooling theory, implementation and best practices.

LED Thermal Management in Commercial and Consumer Lighting Applications

September 27, 2012 at 2:00 p.m. ET

Excess heat directly affects both short-term and long-term LED performance. The short-term effects are color shift and reduced light output, while the long-term effect is accelerated lumen depreciation and thus shortened useful life. Participants will learn how to diagnose and solve thermal issues in consumer and commercial LED applications.

Each of these one-hour online tutorials will include detailed visuals, real world examples, instructions, definitions and references. Audience questions will be answered by the presenters during and after the presentation. One or more ATS PhD-level thermal engineers will be presenting live.

There is no cost to attend these ATS webinars, but virtual seating is limited. Registration is available online at http://www.qats.com, or by calling 1-781-949-2522.

http://qats.com/Training/Webinars/7.aspx