Tag Archives: maxiFLOW

Technical Discussion of ATS Telecom PCB solution

Last year, Advanced Thermal Solutions, Inc. (ATS) was brought in to assist a customer with finding a thermal solution for a PCB that was included in a data center rack being used in the telecommunications industry. The engineers needed to keep in consideration that the board’s two power-dissipating components were on opposite ends and the airflow across the board could be from either side.

Telecom PCB

The PCB layout that ATS engineer Vineet Barot was asked to design a thermal solution for included two components on opposite ends and airflow that could be coming from either direction. (Advanced Thermal Solutions, Inc.)

The original solution had been to use heat sinks embedded with heat pipes, but the client was looking for a more cost-effective and a more reliable solution. The client approached ATS and Field Application Engineer Vineet Barot examined the problem to find the best answer. Using analytical and CFD modeling, he was able to determine that ATS’ patented maxiFLOW™ heat sinks would provide the solution.

Vineet sat down with Marketing Director John O’Day and Marketing Communications Specialist Josh Perry to discuss the challenges that he faced in this project and the importance of using analytical modeling to back up the results of the CFD (computational fluid dynamics).

JP: Thanks for sitting down with us Vineet. How was the project presented to you by the client?
VB: They had a board that was unique – where it would be inserted into a rack, but it could be inserted in either direction. So, we faced a unique challenge because airflow could be from either side of the board. There were two components on either side of the board, so if airflow was coming from one side then component ‘A’ would get hot and from the other side then component ‘B’ would get hot. The other thing was that the customer, who is a very smart thermal engineer, had already set up everything and he was planning on using these heat sinks that had heat pipes embedded in them. The goal was to try and come up with a heat sink that would do the same thing, hopefully without requiring the heat pipes.

JO: Can we talk for a second about the application? You mentioned that airflow was from either side, the board was going to be used in a data center or a telecom node?
VB: It was for a telecom company.

JP: Was there a reason he didn’t want to use a heat pipe?
VB: I think probably cost and reliability. We use heat pipes embedded in the heat sinks too, so it’s not a something we never want to use, but the client wanted to throw that at us and see if we had alternatives.

JP: Can you take us through the board and the challenges that you saw?
VB: As you can see from this slide, there are four main components and two of the hottest ones are on the edge. Airflow can be from right to left or left to right, so which one would be the worst-case scenario?

Telecom PCB

JO: From right to left, I think?
VB: Correct. This one is a straightforward one to figure out because not only is the component smaller but the power is also higher. Even though [air] can go both ways, there’s a worst-case scenario.

This was the customer’s idea – a straight-fin heat sink with a heat pipe and he put one block of heat pipe in there instead of two or three heat pipes that would normally be embedded in there. You can clearly see what the goal was. You have a small component in here, you want to put a large heat sink over the top and you want to spread the heat throughout the base of the heat sink. All the other components are also occupied by straight-fin heat sinks.

JO: Okay, at this point in the analysis, this is the rough estimate of the problem that you face?
VB: This is a straightforward project in terms of problem definition, which can be a big issue sometimes. This time problem definition was clear because the customer had defined the exact heat sink that they wanted to use. It’s not a bad heat sink they just wanted an improvement, cost-wise, reliability-wise.

This is the G600, which is the air going from left to right. The two main components are represented here and we want to make sure that the junction temperatures that the CFD calculated is lower than the maximum junction temperatures allowed, which they were. These heat sinks work. As we always like to do at ATS, we like to have two, independent solutions to verify any problem. That was the CFD result but we also did the analytical modeling to see what these heat sinks are capable of and the percent difference from CFD was less than 10 percent. Twenty percent is the goal typically. If it’s less than 20 percent then you know you’re in the ballpark.

(Advanced Thermal Solutions, Inc.)

(Advanced Thermal Solutions, Inc.)

JO: Do you use a spreadsheet to do these analytical modeling?
VB: HSM, which is our heat sink modeling tool, and then for determining what velocity you have through the fins, the correct way of doing this is to come up with the flow pattern on your own. You go through all the formulas in the book and determine what the flow will be everywhere or figure out what CFD is giving you for the fan curve and check it with analytical modeling. You can look at pressure drop in there, look at the fan curve and see if you’re in the ballpark. You can also check other things in CFD, for example flow balance. Input the flow data into HSM and it will spit out what the thermal performance is for any given heat sink. HSM calculations are based on its internal formulas.

JO: We effectively have a proprietary internal tool. We’ve made a conscious decision to use it.
VB: To actually use it is unique. Not everybody would use it. A lot of people would skip this step and go straight to CFD. We use CFD too but we want to make sure that it’s on the right path.

JP: What do you see as the benefit of doing both analytical and CFD modeling?
VB: CFD, because it’s so easy to use, can be a tool that will lead you astray if you don’t check it because it’s very easy to use and the software can’t tell you if your results are accurate. If you do any calculation, you use a calculator. The calculator is never going to give you a wrong answer but just because you’re using a calculator doesn’t mean that you’re doing the math right. You want to have a secondary answer to verify that what you did is correct.

JP: What was the solution that you came up with for this particular challenge?
VB: We replaced these heat sinks with the heat pipe with maxiFLOW™, no heat pipe needed. One of the little tricks that I used was to off-set the heat sinks a little bit so that these fins are out here and so the airflow here would be kind of unobstructed. And I set this one a little lower so it would have some fins over here, not much, that would be unobstructed. The G600 configurations worked out with the junction temperatures being below what the maximum requirement was without having to use any heat pipes for the main components. There is also a note showing that one of the ancillary components was also below the max. Analytical modeling of that was within 10-11 percent.

The final PCB layout with maxiFLOW heat sinks covering the hottest components on both ends of the board. (Advanced Thermal Solutions, Inc.)

The final PCB layout with maxiFLOW heat sinks covering the hottest components on both ends of the board. (Advanced Thermal Solutions, Inc.)

As you noted, this was the worst-case scenario, going from right to left and you can see because it’s the worst-case scenario this tiny little component here that’s 14 watts that’s having all this pre-heated air going into it, it’s junction temperature was exactly at the maximum allowed. That’s not entirely great. We want to build in a little bit of margin but it was below what was needed.

The conclusion here was that maxiFLOW™ was able to provide enough cooling without needing to use the heat pipes and analytical calculation agreed to less than 20 percent. We would need to explore some alternate designs and strategies if we want to reduce the junction temperature even further because that close to the maximum temperature is uncomfortable. The other idea that we had was to switch the remaining heat sinks, the ones in the middle, which are straight fin, also to maxiFLOW™ to reduce pressure drop and to get more flow through this final component.

(Advanced Thermal Solutions, Inc.)

(Advanced Thermal Solutions, Inc.)

JP: If you have an idea like that, is it something that you broach with the customer?
VB: They really liked the result. If this was a project where the customer said, ‘Yep, we need this,’ then we would have said here’s the initial result and we have an additional strategy. At that point the customer would have said, ‘Yeah this is making us uncomfortable and we need to explore further’ or they would have said, ‘You know what? Fourteen watts is a max and I don’t know if we’ll ever go to 14 watts or the ambient we’re saying is 50°C but we don’t know that it will ever get to 50°C so the fact that you’re at max junction temperature at the worst-case scenario is okay by us.’

JP: Do you always test for the worst-case scenario?
VB: It’s always at the worst-case scenario. It’s always at the max power and maximum ambient temperature.

JP: Was this the first option that we came up with, using maxiFLOW™? Were there other options that we explored?
VB: Pretty much. The way that I approached it was doing the analytical first. You can generate 50 results from analytical modeling in an hour whereas it takes a day and a half for every CFD model – or longer. These numbers here were arrived at with analytical modeling; the height, the width, the top width, were all from analytical modeling, base thickness to measure spreading resistance, all of that was done on HSM and spreadsheets to say this will work.

JP: Do you find that people outside ATS aren’t doing analytical?
VB: No one is doing it, which is really bad because it’s very useful. It gives you a quick idea if it’s acceptable, if this solution is feasible.

To learn more about Advanced Thermal Solutions, Inc. (ATS) consulting services, visit https://www.qats.com/consulting or contact ATS at 781.769.2800 or [email protected].

Case Study: Thermal Management in Harvard Medical School Tissue Analysis Instrumentation

Designers of today’s highly advanced medical diagnostic equipment must overcome many of the same thermal challenges common to telecommunications, industrial and information technology electronics.

In addition, medical diagnostic devices present unique design issues and boundary conditions that factor into thermal solutions. These include isothermal and cyclic temperature demands, precise test repeatability, and maintaining the patient’s safety and comfort.

These kinds of issues were presented by Harvard Medical School to the experts at Advanced Thermal Solutions, Inc. (ATS) when it needed a cooling solution for the diagnostic equipment it was relying on for the analysis and observation of human tissue samples in a controlled laboratory setting. This was the school’s Frozen Tissue Microarrayer System.

ATS engineers had to provide thermal solutions to meet a range of design goals:

• Provide long-term temperature control for tissue samples embedded in an optimum cutting temperature fluid.
• Create a cooling system to maintain tissue samples below -70°C for six hours.
• Ensure operator visibility of the samples.
• Eliminate humidity and frost within the system to prevent sample contamination.

ATS Cooling Solutions

ATS engineers developed highly effective thermal solutions to meet all the design requirements of the diagnostic equipment. A reservoir in the device holds the liquid cooling medium and tissue samples are loaded through an opening at the top. Through a duct, cool air is circulated over the top of the samples to maintain temperature and humidity requirements.

As seen in Fig. 1 (below), the diagnostic system consisted of:

• Frozen tissue coring machine (on the right in the photo)
• Tissue sample loading area at the top of the cooling system (seen on the left)
• Duct system (on both sides of system) to circulate cool air
• Ice/alcohol reservoir at the system’s bottom to contain the cooling medium

Harvard Case Study

Figure 1. Prototype system created by ATS engineers for Harvard Medical School laboratory. (Advanced Thermal Solutions, Inc.)

Conduction Cooling Design

In operation, tissue samples are loaded into removable aluminum cassettes that fit tightly into a metal receiver (top left, Figure 2). The receiver contacts the cassette on five sides which allows for cooling of the samples by conduction. The receiver is lowered into a reservoir containing a slurry of dry ice and ethyl alcohol. Here the receiver is maintained at a constant temperature until the dry ice evaporates. The reservoir is double-walled and insulated to extend the evaporation time of the dry ice.

The receiver also features integral fins that increase surface area for drawing heat downward from the base of the cassettes into the icy slurry (bottom left, Figure 2). These fins are based on the same ATS heat sink design principles used in the company’s high performance maxiFLOW™ heat sinks.

Using analytical modeling, ATS engineers determined that 10 fins were the optimal number for cooling the cassette receiver and its contents. CFD simulations also showed that the 10-fin concept resulted in an optimal design. The engineers validated their analytical and CFD results through empirical testing. It was determined that extending 10 fins into the slurry provided the cooling performance to maintain tissue sample temperatures below the -70°C threshold for 9.75 hours.

Further temperature testing using thermocouples showed only a 2.5°C difference between the coldest points at the bottom of the fins and the tissue samples in the cassette. This proved that the design overcame thermal conduction resistance and could effectively maintain the samples below their critical temperature.

Figure 2. Temperature testing with thermocouples demonstrated that the temperature difference between the bottom of the fins and the top of the cassette, through three intervening layers, was only 2.5°C. This proved that the thermal design was successful. (ATS)

Figure 2. Temperature testing with thermocouples demonstrated that the temperature difference between the bottom of the fins and the top of the cassette, through three intervening layers, was only 2.5°C. This proved that the thermal design was successful. (ATS)

Figure 3. Using a heat sink-specific thermal resistance network ATS determined that the optimal number of fins was 10. (ATS)

Figure 3. Using a heat sink-specific thermal resistance network ATS determined that the optimal number of fins was 10. (ATS)

Convection Cooling Design

The above conduction cooling design provided only part of the solution. There were additional needs to maintain the temperature at the top of the samples and to decrease the relative humidity of the cool air from the ambient air in the lab. ATS engineers designed a convection cooling system to fulfill these requirements.

A heat exchanger was installed with its fins in the dry ice/alcohol slurry and its other side extending into a duct to cool the air passing over it. This approach uses the same cooling medium for both convection and conduction to ensure there is no temperature differential throughout the sample and that the sample is as isothermal as possible.

Air is pushed by a counter-rotating fan through the duct and into the heat exchanger. The heat exchanger forms a thermal link between this air and the slurry mixture. The heat exchanger was designed with an optimum balance between its surface area and the resulting pressure drop to ensure the fan was operating with the most effectiveness.

Once the air passes the heat exchanger, it moves through the ducts and into a diffuser at the top of the system. The diffuser disperses the air over the sample creating a barrier between the tissue and the ambient environment of the lab so outside moisture and heat are not transferred in.

The ATS engineers tested this design using an array of thermocouples and ATS hotwire anemometer Candlestick Sensors connected to an ATS ATVS-2020, a temperature and air velocity scanner. They determined there was too much mixing between the air flowing over the samples and ambient air. The diffuser was redesigned with a new connection to the duct and an optimized outlet radius (see Figure 4).

In the ducts, a molecular sieve desiccant housed in a honeycomb structure was used to reduce the dew point of the air to -84.4°C, which was well below the -72°C air temperature in the duct.

Figure 4. Initial testing led to a redesign of the air diffuser to prevent ambient humidity from mixing with the air over the tissue samples. (ATS)

Figure 4. Initial testing led to a redesign of the air diffuser to prevent ambient humidity from mixing with the air over the tissue samples. (ATS)

Conclusions

ATS engineers performed a final series of tests of the Frozen Tissue Microarrayer System using Candlestick Sensors, thermocouples and the ATVS 2020 scanner. The tissue temperature stayed constant over the required six-hour period and well below the -70°C threshold. In fact, testing determined that the tissue temperature remained below the threshold for nearly eight hours before warming above a usable temperature (Figure 5). The multi-part cooling system was a success, meeting the original design objectives provided by Harvard Medical School.

Figure 5. Final testing showed that the ATS cooling design kept tissue temperature (shown in blue in the graph above) below the -70°C threshold for more than the required six hours. (ATS)

Figure 5. Final testing showed that the ATS cooling design kept tissue temperature (shown in blue in the graph above) below the -70°C threshold for more than the required six hours. (ATS)

The process of designing cooling solutions for the Frozen Tissue Microarrayer demonstrated that thermal design practices used throughout electronics cooling can be applied in the medical device industry. Fin efficiency, thermal resistance, and pressure drop calculations are standard regardless of the application. Thermal solutions should be considered early in the design process so they can be incorporated into the overall system as efficiently as possible.

The experts at ATS used traditional thermal calculations, CFD simulations, empirical testing, and its leading-edge heat sink technology to successfully design the thermal solution for this medical equipment application. The ATS design allowed Harvard Medical School to test tissue samples while meeting its strict requirements.

To learn more about the design, watch the video below:

Download a PDF of this case study at http://www.qats.com/cms/wp-content/uploads/Harvard-Medical-case-study.pdf.

Visit www.qats.com, call 781-769-2800 or email [email protected] to learn more about ATS and its Thermal Management Analysis and Design Services.

Why maxiFLOW Heat Sinks are the Best on the Market

ATS’s maxiFLOW heat sinks provide the highest thermal performance for the physical volume it occupies as compared to other heat sinks designs. The patented, flared fin design reduces junction temperatures by more than 20% compared to standard straight fin, pin fin, or folded fin designs. Watch the video to learn why maxiFLOW heat sinks are superior.

Want to learn more about maxiFLOW heat sinks? Click to the maxiFLOW Main Web Page

How to subscribe to qpedia

New maxiFLOW DC-DC Brick Heat Sinks Ideal for Military-COTS Applications

ATS has recently launched a new product line of maxiFLOW heat sinks, specially designed to cool DC-DC converters. The new line of heat sinks can be used with Vicor’s DC-DC converter Bricks, including their military-COTS applications.

 

Vicor’s Maxi, Mini, and Micro series DC-DC converters are relied upon by over eight thousand OEMs for their proven performance, broad coverage of input and output voltages, ease of mechanical mounting and thermal management flexibility. These converter modules use advanced power processing, control, and packaging technologies to provide the performance, flexibility, and ruggedness expected in a Military COTS product. High frequency ZCS/ZVS switching, advanced power semiconductor packaging, and thermal management provide high-power density with low noise and high efficiency.

maxiFLOW Heat Sink for Half Brick DC-DC Converters

 

ATS’ patented maxiFLOW technology cools millions of BGAs and other PCB components. The same technology is now available for cooling eighth, quarter, half and full brick modules, such as the Micro, Mini, and Maxi series from Vicor. Unlike other converter heat sinks, the patented maxiFLOW heat sink design reduces air pressure drop and provides greater surface area, increasing thermal performance by 30-200%.

Vicor’s Micro, Mini, and Maxi DC-DC Converters

Vicor’s offering of full, half, and quarter-brick modules feature a patented low noise design with the highest reliability and power density available. Fully encapsulated, Maxi, Mini and Micro series DC-DC converters utilize a proprietary spin fill process that assures complete, void free encapsulation making them suitable for the harshest environments. Two grades (H & M) are available with temperatures to -55°C operating and -65°C storage. H & M-Grade modules are qualified to the stringent environmental tests of MIL-STD-810 and MIL-STD-202 and undergo 100% Environment Stress Screening.

By combining technology from industry leaders Vicor and ATS, it can be ensured that DC-DC converters will have superior performance in the harshest environments, which is vital for military and aerospace applications.

To learn more about maxiFLOW Brick DC-DC converter heat sinks, please visit our Power Brick Heat Sink Page or email [email protected], or call us 781-769-2800.

ARM Microprocessors and ATS superGRIP: Attached at the Clip

Advanced Thermal Solutions, Inc., (ATS), has introduced a line of heat sinks compatible with the Sitara ARM Microprocessor family from Texas Instruments.

AM1707 from Texas Instruments

AM1707 from Texas Instruments

The Sitara ARM Microprocessors feature ARM Cortex-8 and ARM9 MPUs, which are used in a wide variety of Industrial, Medical, and Consumer Electronics applications.

The AM17x family consists of low-power ARM microprocessors that enable OEMs and ODMs to maximize product offerings by providing high processing performance life, advanced operating systems and rich user interfaces. Compatible operating systems include Neutrino, Integrity, Windows, Embedded CE, Linux, VXWorks and Android.

ATS patented maxiFLOW heat sinks with superGRIP clip attachment ensure long-term product reliability and maximum performance from the Sitara ARM Microprocessors. maxiFLOW high performance BGA heat sinks feature a low profile, spread fin array that maximizes surface area for more effective convection air cooling. The unique maxiFLOWTM design provides thermal performance that is 30-200% better than conventional heat sinks.

ATS' maxiFLOW Heat Sink with superGRIP Attachment

ATS’ maxiFLOW Heat Sink with superGRIP Attachment

maxiFLOW is available with pre-assembled phase change material, maxiGRIP clip attachments, and superGRIP clip attachments. The superGRIP attachment system features a plastic frame clip that fastens securely around the perimeter of a component and a metal spring clip that slips through a heat sinks fin field and locks securely to both ends of the plastic frame. The resulting superGRIP assembly applies steady even pressure to the component throughout the product lifecycle, improving thermal performance and long-term reliability. The ATS superGRIP heat sink attachment system permits the use of high performance phase changing thermal interface materials that improves heat transfer by as much as 20 times more than typical double-sided adhesive thermal tapes. It also allows for the heat sink to be detached and reattached without damaging the component or the PCB, an important feature for applications where PCB rework and ease of assembly and disassembly are important. The full range of ATS products compatible with Texas Instruments products can be viewed in the new heat sink selection tool on http://qats.com/Distributor/AE-Dist.php