Extruded, Skived or Zipper Fin Heat Sinks

Which is Right for Your Design?

Compare extruded, skived, and zipper fin heat sinks to find the best thermal management solution for electronics, telecom, AI, and power applications.

As power densities continue to increase in electronics, thermal management has become a critical design consideration. Selecting the right heat sink technology can significantly impact system performance, reliability, size, and cost.

Let’s look at the differences between these heat sink technologies and provide guidance on where each solution performs best.

Extruded Heat Sinks

Extruded heat sinks are manufactured by forcing heated aluminum through a shaped die, creating a continuous profile that can be cut to desired lengths. This process produces an integral structure where the base and fins are formed from a single piece of material. [1]

Advantages

  • Lowest manufacturing cost for medium-to-high volume production
  • Excellent mechanical strength due to one-piece construction
  • Wide availability and short lead times
  • Lightweight and corrosion-resistant
  • Suitable for many general-purpose cooling applications

Fig 1 – Extruded Aluminum Heat Sinks are Produced in Continuous Profiles to be Cut to Desired Lengths. [2,3]

Limitations

  • Fin height and fin density are limited by extrusion tooling constraints
  • Typically manufactured from aluminum alloys only
  • Lower thermal performance compared to advanced fin technologies
  • Less effective in high-power or space-constrained designs

Best Applications for Extruded Heat Sinks include:

  • Industrial controls
  • Power supplies
  • LED lighting systems
  • Telecommunications equipment
  • Consumer electronics
  • Moderate-power electronics with natural or forced-air cooling

When cost, simplicity, and manufacturability are primary concerns, extruded heat sinks often provide the best overall value.

Skived Fin Heat Sinks

Skived heat sinks are produced by slicing thin layers of material from a solid metal block and bending them upward to form fins. Because the fins remain attached to the base material, the resulting structure maintains excellent thermal conductivity.

Both aluminum and copper can be used, with copper skived heat sinks offering particularly high thermal performance. [4,5]

Advantages

  • Higher fin density than extrusion
  • Taller, thinner fins improve heat transfer
  • No thermal interface between fins and base
  • Excellent thermal conductivity
  • Can be manufactured from copper for demanding applications

Fig 2 –  Skived Heat Sinks are Produced by Slicing Thin Layers from a Solid Metal Block and Bending Them to Form Fins. [6,7]

Limitations

  • Higher manufacturing cost than extrusions
  • More complex fabrication process
  • Practical limits on fin geometry still exist
  • Heavier when copper is used

Applications that Skived heat sinks excel in:

  • High-performance computing
  • CPUs and GPUs
  • Networking equipment
  • Power conversion systems
  • Medical electronics
  • Aerospace and defense electronics

Designers often select skived heat sinks when thermal performance requirements exceed the capabilities of traditional extrusions but a bonded-fin assembly is unnecessary.

Zipper Fin Heat Sinks

Zipper fin heat sinks use individually stamped metal fins that are mechanically interlocked into grooves in a base plate. The fins resemble the teeth of a zipper, giving the technology its name. This manufacturing approach allows extremely high fin densities and flexible fin geometries that are difficult or impossible to achieve through extrusion or skiving. [8]

Advantages

  • Extremely high fin density
  • Excellent airflow utilization
  • Can be integrated with heat pipes
  • Flexible fin shapes and configurations
  • Available in aluminum, copper, or mixed-material designs
  • Ideal for forced-air cooling applications
  • Supports large cooling surface areas in compact footprints

Figure 3 – Zipper Fin Heat Sinks use Individually Stamped Metal Fins Interlocked into a Base Plate, Shown Here with Integral Heat Pipes. [9,10]

Limitations

  • Higher manufacturing complexity
  • More expensive than standard extrusions
  • Thermal resistance at fin-to-base interfaces can be slightly higher than monolithic designs
  • Typically optimized for systems with active airflow

Zipper fin heat sinks are commonly used in:

  • Data center servers
  • AI and HPC systems
  • Telecom infrastructure
  • Base stations
  • Enterprise networking equipment
  • High-power FPGA and ASIC applications

Whenever maximum cooling performance is required in a constrained space with forced airflow available, zipper fin heat sinks are often the preferred solution.

Key Considerations and Performances of Heat Sink Types

The optimal choice depends on thermal requirements, available space, airflow conditions, and budget. [11,12]

Choose an Extruded heat sink when:

  • Cost is a primary concern
  • Thermal loads are moderate
  • Standard profiles meet design requirements
  • Production volumes are high

Choose a Skived heat sink when:

  • Higher thermal performance is needed
  • Increased fin density is beneficial
  • Copper construction is desirable
  • Space is limited but airflow may be moderate

Choose a Zipper Fin heat sink when:

  • Maximum cooling performance is required
  • Forced airflow is available
  • Fin density must be maximized
  • Thermal constraints are severe

Summary

No single heat sink technology can provide every electronic cooling solution. Extruded heat sinks remain the most economical solution for many designs, while skived heat sinks offer improved thermal performance through higher fin densities and superior material options. For the most demanding thermal challenges, zipper fin heat sinks provide exceptional cooling capability and design flexibility.

Ultimately, the ideal heat sink is one that satisfies thermal requirements while meeting mechanical, manufacturing, and economic objectives. By carefully evaluating airflow, thermal load, space constraints, materials, and cost, engineers can select the most effective thermal management solution for their specific application.

References

  1. Eaton, https://www.eaton.com/us/en-us/catalog/thermal-management-solutions/aluminum-extrusion-profiles.html
  2. Rapid Direct, https://www.youtube.com/watch?v=nIcYV1lDs2w
  3. Davantech, https://www.davantech.com/milling-customized-extruded-aluminum-heatsinks-precision-manufacturing-for-efficient-heat-dissipation/
  4. KenFa Tech, https://www.kenfatech.com/skived-vs-extruded-heat-sink/
  5. Kimsen, https://kimsenglobal.com/skived-fin-heat-sink-technical-deep-dive-for-engineers/
  6. Wekiko-Bythermal, https://www.youtube.com/shorts/RzM_fObq4w0
  7. Heatell, https://www.heatell.com/skived-fin-heat-sink/?utm_source=chatgpt.com
  8. Eaton, https://www.eaton.com/us/en-us/products/thermal-management-solutions/materials-finishes/zipper-tech-overview.html
  9. Gito Machine, https://www.youtube.com/shorts/_JJR477bHjQ
  10. Advanced Thermal Solutions, Inc., https://www.qats.com/Heat-Sinks/Zipper-Fin
  11. Boyd, https://info.boydcorp.com/hubfs/Resources/Resource-Center/Boyd-Guide-to-Heat-Sink-Fabrications-2020-Technical-Paper.pdf
  12. KingKa Tech, https://www.kingkatech.com/Skived-Vs-Extruded-Heat-Sinks-What-Are-The-Key-Differences-id48217376.html

The Importance of Thermal Management

Excess heat has affected electronic devices since their earliest days, becoming more critical with the advent of integrated circuits. Today, excess heat impacts the reliability, performance, and lifespan of devices and circuits across all applications. Common impacts of excess heat in electronics are:

Overheating: This can cause sudden shutdowns or failures. Elevated temperatures damage internal components, leading to permanent failure and potential safety risks—especially in high-power systems such as batteries and automotive electronics.

Lower performance: Overheating devices often throttle to reduce heat, and signal integrity may degrade, resulting in reduced performance. Maintaining operation within the designated temperature range lowers electrical resistance and power consumption while improving energy efficiency.

Shorter lifespans: High temperatures cause differential material expansion and deformation, damaging component structures and internal connections.

Thermal issues can also lead to field recalls and warranty claims. Dense PCB layouts may introduce thermal coupling between components, compounding heat-related risks.

Best practice is to engage thermal management specialists early. Effective thermal management controls and dissipates heat to maintain safe operating temperatures. Cooling solutions vary widely, but viable approaches exist for nearly every application.

Applying Professional Thermal Design

Effective cooling solutions require rigorous analysis at the concept stage, development, and testing. The thermal design process includes analytical modeling, experimental validation, and computational simulation across the full packaging domain—components, PCBs, shelves, chassis, and system enclosures.

Figure 1. CFD Simulation of Forced Airflow Across Areas of a Populated PCB.

Robust thermal design leverages both experimental and computational methods, using lab instrumentation and CFD tools such as FloTHERM, CFdesign, and Icepak, among other commercially available tools.

Empirical methods may include airflow or liquid testing, with measurements of velocity, temperature, and pressure, along with thermography using IR or liquid crystal techniques.

A disciplined, methodical approach consistently delivers strong results across diverse cooling challenges. OEMs can often avoid costly redesigns or recalls through expert thermal review, whether on-demand or via ongoing engineering partnerships. Subscription-based thermal services further accelerate validation and integrate thermal considerations earlier in development. More on these below.

Following are examples of carefully applied cooling design methodology.

Dual-Environment Thermal Analysis of a Sealed Offshore Electronics Enclosure

After detailed analytical modeling to envelop the solutions, CFD analysis was performed on a sealed offshore aquaculture enclosure operating in two passive environments: submerged seawater at 30°C and outdoor air at 40°C. The objective was to determine whether passive cooling could maintain component temperatures below 60°C.

Figure 2. (left) Outer Enclosure Temperature Contours. (center) An Internal Aluminum Sled to Transfer Component Heat to the Outer Enclosure. (right) Velocity Vectors Indicate the Slow Motion of the Internal Air.

The analysis showed the passive design was insufficient for the outdoor air case. Key limitations included weak natural convection and poor internal conduction to the enclosure walls. Hot spot spreading resistance significantly contributed to overall temperature rise.

Addressing the air case would also resolve the submerged case. Recommended improvements:

  1. Increase external surface area with fins or a bonded heat sink
  2. Improve internal conduction and reduce interface resistance
  3. Integrate heat pipes or vapor chambers to reduce spreading resistance

Multi-Cold-Plate Liquid Cooling System Design and Optimization

An EV battery manufacturer developed a 4 kW liquid cooling system with four cold plates integrated into a loop including a heat exchanger, DC-DC converter, and onboard charger. The design required balancing thermal performance, manufacturability, and flow distribution.

Figure 3. Four Cold Plates Receive Chilled Coolant from a Heat Exchanger as Part of a Liquid Loop that Included a DC-DC Converter and On-board Charger.

ATS combined analytical modeling with CFD to optimize cold plate geometry and system flow. Key parameters included tube routing, thermal resistance, and pressure drop.

Figure 4. CFD Simulation of a Revised Cold Plate with 10 Tube Passes and 9 Tube Bends.

A 10-pass serpentine tube design maximized heat transfer while maintaining acceptable pressure drop and manufacturability. Additional improvements included optimized tube diameters and balanced manifold routing.

The study demonstrated that effective kilowatt-scale liquid cooling requires coordinated optimization of geometry, pressure drop, and flow distribution. General findings:

  1. Balanced conduction and convection are critical
  2. Targeted passive changes can yield significant gains
  3. System-level optimization outperforms isolated fixes

CFD-Driven Thermal De-Risking of a Ruggedized Rack System

A baseline-to-optimization CFD study was conducted on a sealed 241 W ruggedized rack system with a 55°C ambient limit. The goal was to identify thermal violations and develop a reliable cooling strategy.

Figure 5. CFD Baseline Model and Surface Temperature Contours of a Ruggedized Rack System.

Through iterative CFD-driven design changes, ATS improved airflow efficiency, heat sink performance, and heat routing. Final modifications included revised heat pipe routing, heat sink replacement, fan reconfiguration, and removal of airflow obstructions. All components achieved thermal compliance.

Figure 6. Surface Temperature Contours of the System’s (left) Original Pin-Fin Heat Sink, and Its Replacement (right) maxiFLOW Heat Sink.

The study showed that sealed systems require holistic optimization across airflow, heat flow routing, fan placement, and heat sink design. General findings:

  1. Analytical modeling identified areas requiring attention and possible solutions
  2. Baseline CFD validated the findings in ‘1’ and identified thermal risks before failure
  3. Heat sink upgrades alone are insufficient without airflow optimization
  4. Iterative CFD enables targeted, low-risk refinement
  5. Final designs improve both compliance and thermal margin

Thermal Optimization of a Passive Aluminum Enclosure

ATS evaluated a sealed passive aluminum enclosure dissipating 75.8 W at 25°C ambient. CFD and parametric analysis identified key thermal constraints and guided optimization.

Figure 7. (left) Distribution of Enclosure Components, (right) Enclosure Baseline Thermal Distribution CFD.

Using 3D CFD with conjugate heat transfer, ATS modeled conduction and natural convection. Results showed that achieving target performance required coordinated improvements across both mechanisms.

Enhancements included improved thermal interface materials, better heat spreading, optimized fin geometry, reduced obstructions, and added vent gaps to enhance natural convection pathways.

Figure 8. The Enclosure Thermal Optimization Included Adding Cross-Cut Venting Gaps to Optimize Natural Convection.

Passive cooling performance is governed by the interaction of internal conduction and external convection. Key limitations included interface resistance and restricted airflow, with diminishing returns from geometry-only changes. Findings:

  1. Balanced conduction and convection are essential
  2. Targeted passive improvements deliver measurable gains
  3. System-level optimization is more effective than isolated changes

Conclusion

Modern electronics—including AI hardware—generate substantial heat loads, making thermal management a first-order design constraint. Large-scale systems such as data centers incorporate cooling from the outset, but thermal design is equally critical at smaller scales.

Figure 9. ATS Thermal Engineers Use Thermochromic Liquid Crystals to Reveal Hot Spots in Electronic Devices. See a Demonstration Video: https://www.youtube.com/watch?v=peewxRlNVqg

Every application presents unique challenges, and thousands of new devices each year require tailored cooling solutions.

When clients have excess heat issues, ATS engineers work closely with them to deliver cost-optimized, practical thermal and mechanical solutions that align with real-world schedules. The objective is consistent: deliver the right solution the first time.

For OEMs and others with continuing needs for thermal engineering, ATS now provides a subscription service. This comes with tiered support levels, ranging from periodic consultation to embedded engineering support within development teams. Contact ATS for more information on the thermal engineering subscription service.

Figure 10. ATS Thermal Engineering Consulting Tiers Match a Manufacturer’s Ongoing Needs.

To see more details on the above cooling applications, and others, see the Advanced Thermal Solutions, Inc. website, https://www.qats.com/Consulting

Cooling Embedded AI Electronics

Embedded AI enables dedicated functions within larger systems. These AI chips power countless devices—robotic arms, smart thermostats, security cameras, medical instruments, drones, and vehicles—enhancing functionality and decision-making at the edge.

ChatGPT is one of the most visited websites in the world. Along with Gemini, Perplexity AI, Grok, and many others, online AI tools are increasingly popular and specialized. This is leading to more power-hungry AI data centers, where hundreds of thousands of GPU chips run at upwards of 1,000 watts each. [1]

But millions of lower power AI chips are running quietly in edge applications all around us.

In smart homes, embedded AI powers thermostats, voice/image recognition, and security. In factories, it drives automated quality control, predictive maintenance, and robotic assembly.

Figure 1 – Embedded AI Systems in Industry Provide Fast, Local Processing to Enhance Production and Safety. [2]

Using local AI inference, these systems make independent decisions, predict outcomes, and automate operations in real time. Connected via the Internet of Things (IoT), they share data and improve interoperability, making homes and factories smarter and more efficient.

AI Technologies in Embedded Systems

  • AI vs. ML: Artificial Intelligence (AI) includes deep learning that uses artificial neural networks to process unstructured data. Machine learning (ML), a subset of AI, focuses on training algorithms to learn from data and adapt over time.
  • Discriminative AI: Embedded systems typically use discriminative AI—optimized for data analysis and evaluation—requiring lower compute power than generative models.

Embedded AI Chips and Cooling Needs

AI processors and modules in embedded applications are not the high-powered versions in data centers. For those, liquid cooling with constant monitoring is essential.

Figure 2 – Intel FPGAs Support Real-Time Deep Learning Inference for Embedded Systems and Data Centers. [4, 5]

Embedded AI processors often come in compact system-on-module (SOM) formats that include CPUs, memory, and specialized chips like GPUs or DSPs. These modules prioritize space efficiency and typically rely on air cooling—either passive or fan-assisted—rather than the liquid cooling found in high-wattage data centers.

Following are some popular AI processors and approved heat sinks.

AMD Kria™ SOMs

The AMD Kria K24 SOM runs on as little as 2.5 watts and typically uses a passive (fan-less) heat sink. Its low power and compact size allow it to be installed close to the processes it manages, such as intelligent motor control. The more capable Kria K26 SOM supports higher-end tasks like machine vision and robotic planning and may require active cooling. [6]

Figure 3 –The AMD Kria K24 and K26 SOMs Can Be Used for Sophisticated Robotic Applications. The K24 Provides Intelligent Motor Control. The K26 Manages Complex Machine Vision. [6]

In the above robotics application, different heat sinks are available to cool the K24 and K26 SOMs. These come in varieties for providing optimum levels of air cooling, as well as for fitting available spaces. The K24 SOM can be cooled with a passive (fan-less) sink. Depending on its application, the K26 SOM may need an active heat sink. Examples of heat sinks for cooling the K26 SOM are below. [7]

Figure 4 – Fan-assisted Heat Sinks, Like the Above ATS Model May be Needed for Cooling AMD Kria K26 System-on-Modules. In Some Applications, Passive (fan-less) Heat Sinks are Sufficient.

Figure 5 – Three Passive Heat Sinks Developed to Cool AMD Kria K24 SOMs. The Taller Finned Versions Provide More Cooling Performance but Need More Headroom and are Heavier. [8]

NVIDIA Jetson Modules

Widely used NVIDIA Jetson modules power a wide range of AI in embedded systems. These compact, powerful modules enable AI solutions in manufacturing, logistics, and healthcare. They leverage NVIDIA’s GPU technology for accelerated AI computations.

In the Jetson module family, Orin systems are specifically engineered to provide high-speed support for a wide range of sensors, enabling seamless integration with various edge AI applications.

One of these, the Jetson AGX Orin series, uses just 15 to 75 watts of power depending on the specific module, workload, and external factors such as local temperatures. They’re designed for passive cooling to manage heat in applications with prolonged operating temperatures, where fans could be affected by dust and debris. [9]

Figure 6 – Top: NVIDIA’s Jetson AGX Orin Module Features an AI Accelerator Graphic Chip and an  Ampere GPU Architecture Chip in One Package. It Can be Passively Cooled with a Specially-Designed, NVIDIA-Approved ATS Heat Sink. [9,10]

Bottom: The Many Uses of Orin Modules Include Embedding in Zipline Delivery Drones [11]

The Orin, another Jetson module, is a small, powerful computer for embedded AI applications connected to the IoT. Its capabilities include deep learning, computer vision, graphics, and multimedia.

Figure 7 – Top: An NVIDIA Jetson Orin Nano Module and a Specially-Designed ATS Active Heat Sink. [12, 10] Bottom: Multiple Security Cameras and Sensors Feed Visual Data to an Orin Nano Module Whose AI Detects Unusual Activities. [13]

One application for Orin Nano modules is in security surveillance systems. Cameras and sensors are placed in strategic locations. The Orin Nano module processes their visual data, detecting unusual activities and triggering alerts when identified by the AI.

When Air Cooling Isn’t Enough

One exception to air cooling for embedded processors is in some smart phones. Tasked to perform ever more functions, including AI, their increasingly powerful chips require higher performance cooling.

For example, Qualcomm Snapdragon 8-series chips, used in phones like the OnePlus 13, generate significant heat under heavy loads. Vapor chambers help dissipate that heat across a broader surface for effective cooling without active fans.

Figure 8 – Top: The Top-Rated OnePlus 13 Phone Features a Qualcomm Snapdragon 8 Elite Chip. Botton: A Teardown Video Reveals the Vapor Chamber for Cooling the Snapdragon Chip. [14,15]

Embedded AI Efficiency

Embedded AI continues to gain ground due to its compact design, low latency, and localized processing. Its benefits include:

  • Reduced network load by transmitting processed insights rather than raw data
  • Lower system cost vs. cloud-based AI
  • Lower power consumption, enabling simpler and cheaper cooling solutions

With AI now embedded across sectors—from smart homes to drones to industrial robotics—thermal management solutions are evolving alongside to ensure performance and longevity.

References

  1. MIT Technology Review, https://www.technologyreview.com/2025/05/20/1116327/ai-energy-usage-climate-footprint-big-tech/
  2. GIGAIPC, https://www.gigaipc.com/en/solution-detail/Machine-Vision/
  3. Embedded, https://www.embedded.com/ai-efficiency-will-depend-on-model-size/
  4. Intel, https://www.intel.com/content/www/us/en/software/programmable/fpga-ai-suite/overview.html
  5. Mirabilis Design, https://www.mirabilisdesign.com/intel-fpga-neural-processor-ai/
  6. Electronic Design, https://www.electronicdesign.com/technologies/industrial/boards/video/21273991/a-look-inside-amds-kria-k24-system-on-module
  7. AMD, https://www.technologyreview.com/2025/05/20/1116327/ai-energy-usage-climate-footprint-big-tech/
  8. Advanced Thermal Solutions, Inc., https://www.qats.com/Heat-Sinks/Device-Specific-AMD-Kria-K26
  9. NVIDIA, https://www.nvidia.com/en-us/autonomous-machines/embedded-systems/jetson-orin/
  10. Advanced Thermal Solutions, Inc., https://www.qats.com/Heat-Sinks/Device-Specific-NVIDIA
  11. Things Embedded, https://things-embedded.com/us/nvidia-jetson/orin/agx/
  12. NVIDIA, https://www.nvidia.com/en-us/autonomous-machines/embedded-systems/jetson-nano/product-development/
  13. Prox PC, https://www.proxpc.com/blogs/case-studies-real-world-applications-of-nvidia-jetson-orin-nano
  14. Tom’s Guide, https://www.tomsguide.com/phones/oneplus-phones/oneplus-13-is-official-and-one-of-the-first-snapdragon-8-elite-powered-phones
  15.  PBKreviews, https://www.youtube.com/watch?v=WqJq3-ngL2Q

Cooling AI Data Centers

How important are AI data centers? In just months, Elon Musk’s xAI team converted a factory outside Memphis into a cutting-edge, 100,000-GPU center for training the Colossus supercomputer—home to the Grok chatbot.

Initially powered by temporary gas turbines (later replaced by grid power), Colossus installed its first 100,000 chips in only 19 days, drawing praise from NVIDIA CEO Jensen Huang. Today, it operates 200,000 GPUs, with plans to reach 1 million GPUs by the end of 2025. [1]

Figure 1 – Elon Musk’s 1 Million Sq Ft xAI Colossus Supercomputer Facility near Memphis, TN. [1]

There are about 12,000 data centers throughout the world, nearly half of them in the United States. Now, more and more of these are being built or retrofitted for AI-specific workloads. Leaders include Musk’s xAI, Microsoft, Meta, Google, Amazon, OpenAI, and others.

High power is essential for such operations, and like computational electronics of all sizes heat issues need to be resolved.

GenAI

A key driver of data center growth is Generative AI (GenAI)—AI that creates text, images, audio, video, and code using deep learning. Chatbots and large language model ChatGPT are examples of GenAI, along with text-to-image models that generate images from written descriptions.

Managing all this is possible from new generations of processors, mainly GPUs. They all draw on higher levels of power and generate higher amounts of heat.

Figure 2 – Advanced AI Processor, the NVIDIA GH200 Grace Hopper Superchip with Integrated CPU to Increase Speed and Performance. [2,3]

AI data centers prioritize HPC hardware: GPUs, FPGAs, ASICs, and ultra-fast networking. Compared to CPUs (150–200 W), today’s AI GPUs often run >1,000 W.  . To handle massive datasets and complex computations in real-time they need significant power and cooling infrastructure.

Data Center Cooling Basics

Traditional HVAC was sufficient for older CPU-driven data centers. Today’s AI GPUs demand far more cooling, both at the chip level and facility-wide. This has propelled a need for more efficient thermal management systems at both the micro (server board and chip) and macro (server rack and facility) levels. [4]

Figure 3 – The Colossus AI Supercomputer Now Runs 200,000 GPUs. It Operates at 150MW Power, Equivalent to 80,000 Households. [5]

At Colossus, Supermicro 4U servers house NVIDIA Hopper GPUs cooled by:

  • Cold plates
  • Coolant distribution manifolds (1U between each server)
  • Coolant distribution units (CDUs) with redundant pumps at each rack base [6]

Each 4U server is equipped with eight NVIDIA H100 Tensor Core GPUs. Each rack contains eight 4U servers, totaling 64 GPUs per rack.

Between every server is a 1U manifold for liquid cooling. They connect with CDUs, heat-exchanging Coolant Distribution Units at the bottom of each rack that include a redundant pumping system. The choice of coolant is determined by a range of hardware and environmental factors.

Figure 4 – Each Colossus Rack Contains Eight 4U Servers, Totaling 64 GPUs Per Rack. Between Each Server is a 1U Manifold for Liquid Cooling. [7]
Figure 5 – The Base of Each Rack Has a 4U CDU Pumping System with Redundant Liquid Cooling. [7]

Role of Cooling Fans

Fans remain essential for DIMMs, power supplies, controllers, and NICs.

Figure 6 – Rear Door Liquid-Cooled Heat Exchangers. [7]

At Colossus, fans in the servers pull cooler air from the front of the rack, and exhaust the air at the rear of the server. From there, the air is pulled through rear door heat exchangers. The heat exchangers pass warm air through a liquid-cooled, finned heat exchanger/radiator, lowering its temperature before it exits the rack.

Direct-to-Chip Cooling

NVIDIA’s DGX H100 and H200 server systems feature eight GPUs and two CPUs that must run between 5°C and 30°C. An AI data center with a high rack density houses thousands of these systems performing HPC tasks at maximum load. Direct liquid cooling solutions are required.

Figure 7 – An NVIDIA DGX H100/H200 System Featuring Eight GPUs [8]
Figure 8 – The NVIDIA H100 SmartPlate Connects to a Liquid Cooling System to Bring Microconvective Chip-Level Cooling That Outperforms Air Cooling by 82%. [9]

Direct liquid cooling (cold plates contacting the GPU die) is the most effective method—outperforming air cooling by 82%. It is preferred for high-density deployments of the H100 or GH200.

Scalable Cooling Modules

Colossus represents the world’s largest liquid-cooled AI cluster, using NVIDIA + Supermicro technology. For smaller AI data centers, Cooling Distribution Modules (CDMs) provide a compact, self-contained solution.

Figure 9 – The iCDM-X Cooling Distribution Module from ATS Includes Pumps, Heat Exchanger and Liquid Coolant for Managing Heat from AI GPUs and Other Components. [10]

Most AI data centers are smaller, and power and cooling needs are lower, but essential. Many heat issues can be resolved using self-contained Cooling Distribution Modules.

The compact iCDM-X cooling distribution module provides up to 1.6MW of cooling for a wide range of AI GPUs and other chips. The module measures and logs all important liquid cooling parameters. It uses using just 3kW of power, and no external coolant is required.

These modules include:

•         Pumps

•         Heat exchangers

•         Cold plates

•         Digital monitoring (temp, pressure, flow)

Their sole external component is one or more cold plates removing heat from AI chips. ATS provides an industry-leading selection of custom and standard cold plates, including the high-performing ICEcrystal series.

Figure 10 – The ICEcrystal Cold Plates Series from ATS Provide 1.5 kW of Jet Impingement Liquid Cooling Directly onto AI Chip Hotspots.

Cooling Edge AI and Embedded Applications

AI isn’t just for big data centers—edge AI, robotics, and embedded systems (e.g., NVIDIA Jetson Orin, AMD Kria K26) use processors running under 100 W. These are effectively cooled with heat sinks and fan sinks from suppliers like Advanced Thermal Solutions. [11]

Figure 11 – High Performance Heat Sinks for NVIDIA and AMD AI Processors in Embedded and Edge Applications. [11]

NVIDIA also partners with Lenovo, whose 6th-gen Neptune cooling system enables full liquid cooling (fanless) across its ThinkSystem SC777 V4 servers—targeting enterprise deployments with NVIDIA Blackwell + GB200 GPUs. [12]

Figure 12 – Lenovo’s Neptune Direct Water Cooling Removes Heat from Power Supplies, for Completely Fanless Operation. [12]

Benefits gained from the Neptune system include:

  • Full system cooling (GPUs, CPUs, memory, I/O, storage, regulators)
  • Efficient for 10-trillion-parameter models
  • Improved performance, energy efficiency, and reliability

Conclusion

With surging demand, AI data centers are now a major construction focus. Historically, cooling problems are the #2 cause of data center downtime (behind power issues). With the high power needed for AI computing, these builds should carefully fit with their local communities in terms of electrical needs and sources, and water consumption. [13]

AI workloads will increase U.S. data center power demand by 165% by 2030 (Goldman Sachs), with nearly double 2022 levels (IBM/Newmark). Sustainable design and resource-conscious cooling are essential for the next wave of AI infrastructure. [14,15]

References

1. The Guardian, https://www.theguardian.com/technology/2025/apr/24/elon-musk-xai-memphis

2. Fibermall, https://www.fibermall.com/blog/gh200-nvidia.htm

3. NVIDA, https://resources.nvidia.com/en-us-grace-cpu/grace-hopper-superchip?ncid=no-ncid

4. ID Tech Ex, https://www.idtechex.com/en/research-report/thermal-management-for-data-centers-2025-2035-technologies-markets-and-opportunities/1036

5. Data Center Frontier, https://www.datacenterfrontier.com/machine-learning/article/55244139/the-colossus-ai-supercomputer-elon-musks-drive-toward-data-center-ai-technology-domination

6. Supermicro, https://learn-more.supermicro.com/data-center-stories/how-supermicro-built-the-xai-colossus-supercomputer

7. Serve The Home, https://www.servethehome.com/inside-100000-nvidia-gpu-xai-colossus-cluster-supermicro-helped-build-for-elon-musk/2/

8. Naddod, https://www.naddod.com/blog/introduction-to-nvidia-dgx-h100-h200-system

9. Flex, https://flex.com/resources/flex-and-jetcool-partner-to-develop-liquid-cooling-ready-servers-for-ai-and-high-density-workloads

10. Advanced Thermal Solutions, https://www.qats.com/Products/Liquid-Cooling/iCDM

11. Advanced Thermal Solutions, https://www.qats.com/Heat-Sinks/Device-Specific-Freescale

12. Lenovo, https://www.lenovo.com/us/en/servers-storage/neptune/?orgRef=https%253A%252F%252Fwww.google.com%252F

13. Deloitte, https://www2.deloitte.com/us/en/insights/industry/technology/technology-media-and-telecom-predictions/2025/genai-power-consumption-creates-need-for-more-sustainable-data-centers.html

14.GoldmanSachs, https://www.goldmansachs.com/insights/articles/ai-to-drive-165-increase-in-data-center-power-demand-by-2030

15. Newmark, https://www.nmrk.com/insights/market-report/2023-u-s-data-center-market-overview-market-clusters

Cooling Hot Electronics with Cold Plates

Cold plates have been used for thermal management since the Apollo moon missions in the 1960s. Today, they serve a critical role in cooling high-performance electronics across many industries.

Power electronic devices generate significant heat, and if their chips exceed safe temperature limits, system reliability and longevity are compromised. Effective thermal management is essential, as lowering a chip’s junction temperature by just 10°C can double its operational life.

Cold plates offer highly efficient, localized cooling by transferring heat from hot components—such as power semiconductors—into a liquid coolant flowing through the plate. The heated liquid then moves to a remote heat exchanger, where it cools before recirculating back to the cold plate.

Compared to forced-air cooling, cold plates deliver superior thermal performance. They are typically smaller, quieter, and lighter than fan-based systems, making them an attractive solution in compact or noise-sensitive environments.

Most cold plates consist of thin-walled aluminum or copper blocks with internal channels or tubing for coolant flow. As liquid moves through the plate, it absorbs heat from the attached components and carries it away for external dissipation. Modern designs often use mini-channels instead of traditional tubing. These intricate internal pathways maximize surface contact with the coolant, improving heat transfer and cooling efficiency.

Figure 1 – Cold Plates are Part of a Liquid Cooling Loop that Includes a Pump for Fluid Circulation and a Heat Exchanger to Remove Heat from the Flowing Coolant. [ATS]

More advanced cold plates feature mini-channels in place of tubing. These designs can better match applications and more efficiently transfer heat into the coolant.

Figure 2 – A Cold Plate with Internal Mini-Channels Provides a High Rate of Thermal Transfer to Remove More Component Heat. [ATS]

Tubed Cold Plates Cool Hot Electronics

Embedded tube designs are the simplest cold plates. They feature a stainless steel or copper tube coiled and set into grooves inside a metal base plate. The tubes can be routed in different pathways to optimize thermal transfer performance. The flowing coolant moves heat from the component, away from the cold plate and over to a heat exchanger where it is cooled before being pumped back to the plate.

Figure 3 – A Tubed Cold Plate Can Consist of Copper or Stainless-Steel Tubing Pressed or Embedded in a Metal Plate. [ATS]

These tubed cold plates are cost-effective solutions for low- to moderate-power applications and are ideal for use in automotive, instrumentation, and UPS systems. ATS offers models ranging from 57–914 mm in length and 57–198 mm in width, with push-to-connect fittings for easy installation.

A variation of this design features thermally conductive epoxy completely covering the tubing and flush with the plate’s surface. This not only improves thermal contact but also provides environmental protection by sealing the tube within the plate.

Figure 4 – A Cold Plate’s Tubing Can be Buried and Covered with a Thermally Conductive Epoxy Layer. [1]

Custom Cold Plates Provide Best Cooling Solutions

For more demanding applications—such as cooling BGAs, LEDs, or high-power modules—custom cold plates offer the best performance. These can include embedded tubing or submerged internal fins, which increase surface area and create turbulence to enhance heat transfer.

Figure 5. Custom Liquid Cold Plate with Inlaid Copper Tubing Provides Heat Transfer Away from Hot Electronics [2]

One example uses tightly spaced aluminum pin fins to generate turbulence with minimal pressure drop, achieving high thermal performance while keeping the plate compact. Another design incorporates internal turbulators tailored for IGBT modules, further improving coolant flow and heat dissipation.

ATS designs and manufactures custom cold plates in collaboration with customers or based on in-house thermal analysis. These designs can include complex internal geometries such as microchannels or gyroid lattices, like the 3D-printed cold plate created for race car IGBT cooling—an approach that improves flow guidance while reducing weight.

Figure 6. Close-spaced Pin Fins with Complex Geometry Create Turbulence with Low Flow Rate Values Inside Submerged Fin Cold Plates. [3]
Figure 7. A Custom IGBT-Cooling Cold Plate Features Internal Turbulators to Optimize Coolant Turbulence and Heat Transfer. [4]

ATS constructs cold plates to customer designs and those developed in partnership with our own thermal engineers. ATS coolant-based cold plates can include internal tubing and microchannels in closed loop systems.

Figure 8. Dual-Sided Cold Plates Cool Components on Both of Their Mounting Sides. [ATS]

Dual-sided high-flow cold plates provide equal cooling performance for components mounted on both sides of the plate, increasing efficiency, space savings and economy. The cold plates can be used with coolant flow rates up to 4 gal/min, and provide thermal resistance as low as 0.0021°C/W. [5]

Figure 9 – This 3D-Printed Metal Cold Plate Cools IGBTs on a Race Car. It Features a Gyroid Lattice That Guides Internal Coolant Flow While Reducing the Overall Weight [6]

DIY Cold Plates Optimize Component Cooling

ATS also offers DIY (do it yourself) cold plates with modular dimensions and pre-defined drill zones. Engineers can customize mounting locations to match specific components. Once the ideal configuration is determined, ATS can mass-produce the cold plate to match exact specifications.

Figure 10 – Do It Yourself Cold Plates from ATS Feature Drill Zones for Precision Matching to Heat Sources, and No Drill Zones to Protect Internal Coolant Flow Channels. [ATS]

The Complete Liquid Cooling Loop

Cold plates are just one part of a complete liquid cooling system. As electronics demand more efficient cooling, liquid-based systems are increasingly replacing air-based solutions. A functional loop includes a pump, reservoir, and heat exchanger to remove heat from the circulating fluid.

Figure 11 – A Liquid Cooling Loop Featuring Cold Plates. This is Implemented in Avionics on F-16 Fighting Falcon Jets. [7]

These systems are becoming more cost-effective and safer, making liquid cooling viable for a broader range of applications. Cold plates serve as a critical stage in these loops, offering simplicity, versatility, and high thermal performance.

Plug and Play Liquid Loops

For streamlined implementation, ATS offers the Industrial Cooling Distribution Module™ (iCDM™)—a fully integrated liquid cooling loop in one compact, portable unit. It includes the pump, heat exchanger, reservoir, precision controls, and monitoring displays, eliminating the need to purchase and configure components separately.

Figure 12 – The New Industrial Cooling Distribution Module Contains the Pump, Heat Exchanger, Reservoir and Controls for Managing Coolants in Liquid Cooling Loops. [ATS]

The iCDM connects directly to cold plates or chassis-based cooling systems. It supports models with cooling capacities of 10 kW and 20 kW, each holding up to 2 liters of coolant. The system is compatible with a wide range of wetted materials, allowing flexible deployment across industries. A next-generation iCDM, available soon, is fully automated, with significantly increased cooling capacities up to 1.4MW.

Conclusion

Cold plates can provide essential electronics cooling because of their design versatility and the power of liquid cooling. AI chip cooling cold plates will soon be available for this growing and demanding arena.

ATS engineers are experts in matching thermal solutions to system needs, offering a wide portfolio that includes cold plates, vapor chambers, coolant chillers, and complete liquid loop systems. Whether liquid cooling is the best solution depends on the specific application, and ATS provides detailed analysis to help customers make informed decisions.

References

  1. Wakefield Thermal, http://www.wakefield-vette.com/products/liquid-cooling/liquid-cold-plates/standard-liquid-cold-plates.aspx
  2. Baknor, https://www.baknorthermal.com/liquid-cold-plates-various-channel-options/
  3. COOLTECH, http://www.cooltech.it/products/liquid-cold-plates/
  4. Boyd Corp., https://www.boydcorp.com/thermal/liquid-cooling-systems/liquid-cold-plates.html
  5. ATS, https://www.qats.com/Products/Liquid-Cooling/Dual-Sided-Cold-Plates
  6. nTop, https://www.ntop.com/resources/case-studies/cold-plate-automotive-power-electronics/
  7. ThermOmegaTech, https://www.tot-ad.com/avionics-cooling/