#JustChilling: ATS Recirculating and Immersion Chillers for Liquid Cooling Systems

ATS Chillers

Advanced Thermal Solutions, Inc. has a line of recirculating and immersion chillers for conditioning the coolant in liquid cooling systems. (Advanced Thermal Solutions, Inc.)


ATS offers a variety of chillers, including the CHILL V and CHILL iM series, for conditioning the coolant in liquid cooling systems. The ATS-CHILL V series, including the ATS-Chill150V, ATS-Chill300V, and ATS-Chill600V, are re-circulating, vapor compression chillers that offers precise coolant temperature control using a PID controller. The ATS-CHILL iM is an immersion chiller for precise control of the bath temperature by immersing the evaporator in a fluid bath.

Learn more about ATS recirculating and immersion chillers in this recent blog post or in the video below:

ATS Liquid Cooling Products

In addition to chillers, ATS has a complete product offering for Liquid Cooling Closed Loop Systems, including flow meters, leak detectors, heat exhangers, and cold plates. ATS can also design off-the-shelf or custom liquid cooling systems to meet the thermal needs of a project.

ATS 3-Core design approach identifies the type of cooling required at the analysis level and informs the client of its options, saving cost and time on design iteration and simulation verification. Once it is determined that liquid cooling is the option to pursue, the ATS design team identifies all the required components of the liquid loop, as well its packaging requirements and integration in the system.

ATS offers a complete array of off-the-shelf liquid loop components that can be readily deployed or custom-designed to meet the thermal requirements of the system. Subsequent integration of the liquid loop into the system provides the customer with a turn-key option for thermal management of their system.

Don’t get burned! Take advantage of ATS expertise in liquid and air cooling to ensure proper thermal management for your project.

For more information about Advanced Thermal Solutions, Inc. thermal management consulting and design services, visit www.qats.com or contact ATS at 781.769.2800 or ats-hq@qats.com.

Cold Plates and Recirculating Chillers for Liquid Cooling Systems

Recirculating Chillers

ATS cold plates and recirculating chillers can be used in closed loop liquid cooling systems for high-powered electronics. (Advanced Thermal Solutions, Inc.)


The miniaturization of high-powered electronics and the requisite component density that entails have led engineers to explore new cooling methods of increasing complexity. As a result, there is a growing trend in thermal management of electronics to explore more liquid cooling systems and the reintroduction, and re-imagining, of cold plate technology, which has a long history that includes its use on the Apollo 11 space shuttle.i

Thermal management of high-powered electronics is a critical component of a design process. Ensuring the proper cooling of a device optimizes its performance and extends MTBF. In order for a system to work properly, engineers need to establish its thermal parameters from the system down to the junction temperature of the hottest devices. The use of cold plates in closed loop liquid cooling systems has become a common and successful means to insure those temperatures are managed.

Cold plate technology has come a long way since the 1960s. At their most basic level, they are metal blocks (generally aluminum or copper) that have inlets and outlets and internal tubing to allow liquid coolant to flow through. Cold plates are placed on top of a component that requires cooling, absorbing and dissipating the heat from the component to the liquid that is then cycled through the system.

In recent years, there have been many developments in cold plate technology, including the use of microchannels to lower thermal resistanceii or the inclusion of nanofluids in the liquid cooling loop to improve its heat transfer capabilities.iii

An article from the October 2007 issue of Qpedia Thermal eMagazine detailed the basic components of a closed loop liquid cooling system, including:

• A cold plate or liquid block to absorb and transfer the heat from the source
• A pump to circulate the fluid in the system
• A heat exchanger to transfer heat from the liquid to the air
• A radiator fan to remove the heat in then liquid-to-air heat exchanger

The article continued, “Because of the large surface involved, coldplate applications at the board level have been straight forward…Design efforts for external coldplates to be used at the component level have greatly exceeded those for PCB level coldplates.”

Exploring liquid cooling loops at the board or the component level, according to the author, requires an examination of the heat load and junction temperature requirements and ensuring that air cooling will not suffice to meet those thermal needs.iv

To read the full article on “Closed Loop Liquid Cooling for High-Powered Electronics,” click http://coolingzone.com/blog/wp-content/uploads/2017/01/Qpedia_Oct07_Closed_Loop_liquid_cooling_
for_high_power_electronics.pdf
.

Chillers provide additional support for liquid cooling loops

In order to increase the effectiveness of the cold plate and of the liquid cooling loop, recirculating chillers can be added to condition the coolant before it heads back into the cold plate. The standard refrigeration cycle of recirculating chillers is displayed below in Fig. 1.

Chiller,s Cold Plates

Fig. 1. The standard refrigeration cycle for recirculating chillers. (Adavanced Thermal Solutions, Inc.)

Several companies have introduced recirculating chillers to the market in recent years, including ThermoFisher, PolyScience, Laird, Lytron, and Advanced Thermal Solutions, Inc. (ATS). Each of the chiller lines has similarities but also unique features that fit different applications.

In order to select the right chiller, Process-Cooling.com warns that it is important to avoid “sticker shock” because of testing conditions that are ideal rather than based on real-world applications. The site suggests a safety factor of as much as 25 percent on temperature ranges to account for environmental losses and to ensure adequate cooling capacity.v

The site also noted the importance of speaking with manufacturers about the cooling capacity that is needed, the required temperature range, the heat load of the application, the length and size of the pipe/tubing, and any elevation changes.

“Look for a chiller with an internal pump-pressure adjustment,” the article stated. “This feature enables the operator to dial down the external supply pressure to a level that is acceptable for the application. Because the remaining flow diverts internally into the chiller bath tank, no damage will result to the chiller pump or the external application.”

When trying to decide on the right size chiller for your particular application, there are several formulas that can help make the process easier. Bob Casto of Cold Shot Chillers, writing for CoolingBestPractices.com, gave one calculation for industrial operations. First, determine the change in temperature (ΔT), then the BTU/hour (Gallons per hour X 8.33 X ΔT), then calculate the tons of cooling ([BTU/hr]/12,000), and finally oversize by 20 percent (Tons X 1.20).vi

Not every application will require industrial capacity, so for smaller, more portable chillers, Julabo.com had a secondary calculation for required capacity (Q).

Q=[(rV cp)material+(rV cp)bath fluid]ΔT/t

In the above equation, r equals density, V equals volume, cp equals constant-pressure specific heat, ΔT equals the change in temperature, and t equals time. “Typically, a safety factor of 20-30% extra cooling capacity is specified for the chilling system,” the article continued. “This extra cooling capacity should be calculated for the lowest temperature required in the process or application.”vii

Comparison of Industry Standard Recirculating Chillers

Recirculating Chillers

Applications for liquid cooling systems with chillers

Recirculating chillers offer liquid cooling loops precise temperature control and coupled with cold plates can dissipate a large amount of heat from a component or system. This makes chillers (and liquid cooling loops in general) useful to a wide range of applications, including applications with demanding requirements for temperature range, reliability, and consistency.

Chillers have been part of liquid cooling systems for high-powered lasers for a number of years to ensure proper output wavelength and optimal power.viiiix To ensure optimal performance, it is important to consider safety features, such as the automatic shut-off on the ATS-Chill 150V that protects against over-pressure and compressor overload. Other laser-related applications include but are not limited to Deep draw presses, EDM, Grinding, Induction heating and ovens, Metallurgy, Polishing, Spindles, Thermal spray, and Welding.x

Machine hydraulics cooling and semiconductors also benefit from the inclusion of chillers in liquid cooling loops. Applications include CVD/PVD, Etch/Ashing, Wet Etch, Implant, Inductively Coupled Plasma and Atomic Absorption Spectrometry (ICP/AA), Lithography, Mass Spectroscopy (MS), Crystal Growing, Cutting/Dicing, Die Packaging and Die Testing, and Polishing/Grinding.xi

One of the most prominent applications for liquid cooling, heat exchangers, cold plates, and chillers is in medical equipment. As outlined in an ATS case study,xii medical diagnostic and laboratory equipment requires cyclic temperature demands and precise repeatability, as well as providing comfort for patients. For Harvard Medical School, ATS engineers needed to design a system that could maintain a temperature of -70°C for more than six hours. Using a cold plate with a liquid cooling loop that included a heat exchanger, the engineers were able to successfully meet the system requirements.

Liquid cooling with chillers are also being used for medical imaging equipment and biotechnology testing in order to provide accurate results. ATS CEO and President Dr. Kaveh Azar will discuss the “Thermal Management of Medical Electronics” in a free webinar on Jan. 26 at 2 p.m. For more information or to register for the webinar, click https://www.qats.com/Training/Webinars.

Conclusion

Closed loop liquid cooling systems are not new but are gaining in popularity as heat dissipation demands continue to rise. Using cold plate technology with recirculating chillers, such as the ATS-Chill150V, ATS-Chill300V, and the ATS-Chill600V, to condition the coolant in the system can offer enhanced heat transfer capability.

Portable and easy to use, ATS vapor compression chillers are air-cooled to eliminate costly water-cooling circuits and feature a front LED display panel that allows users to keep track of pressure drop between inlet and outlet and the coolant level. They each use a PID controller.

Recirculating Chillers

For more information about Advanced Thermal Solutions, Inc. thermal management consulting and design services, visit www.qats.com or contact ATS at 781.769.2800 or ats-hq@qats.com.

References
i http://history.nasa.gov/SP-287/ch1.htm
ii https://heatsinks.files.wordpress.com/2010/03/qpedia_0309_web.pdf#page=12
iii http://www.sciencedirect.com/science/article/pii/S0142727X99000673
iv https://www.qats.com/cpanel/UploadedPdf/Qpedia_Thermal_eMagazine_0610_V2_lorez1.pdf#page=16
v http://www.process-cooling.com/articles/87261-chillers-evaluation-and-analysis-keys-to-selecting-a-winning-chiller?v=preview
vi http://www.coolingbestpractices.com/industries/plastics-and-rubber/5-sizing-steps-chillers-plastic-process-cooling
vii http://www.julabo.com/us/blog/2016/sizing-a-cooling-system-control-temperature-process-heating-operations
viii http://www.laserfocusworld.com/articles/print/volume-37/issue-6/features/instruments-accessories/keeping-your-laser-cool0151selecting-a-chiller.html
ix https://www.electrooptics.com/feature/keeping-it-cool
x http://www.lytron.com/Industries/Laser-Cooling
xi http://www.lytron.com/Industries/Semiconductor-Cooling
xii https://www.qats.com/cms/2016/10/04/case-study-thermal-management-harvard-medical-school-tissue-analysis-instrumentation/

Holiday Sale: 25 % Off Qpedia Book Series!

 

coolingZONE is running a holiday promotion on the Qpedia Book Series, discounting 25% off the normal retail value until December 31, 2012. Qpedia Thermal eMagazine is the official media sponsor of coolingZONE. The Qpedia book series provides an expert resource for engineering professionals, professors, students and others who want to learn more about the theories and applications of electronics thermal management.

The four volume set contains nearly 200 in-depth articles, researched and written by veteran engineers. They address the most critical areas of electronics cooling, with a wide spectrum of topics and thorough technical explanation. Each article features color illustrations and images along with important thermal calculations and formulas.

Qpedia Volume 1 topic highlights:

– Heat sink design

– Pool boiling

– Sensors

– Thermal chassis

– Pitot tubes

– Heat transfer

Qpedia Volume 2 topic highlights:

– Thermal grease

– Vapor chamber cooling

– Liquid cooling

– Natural convection cooling

– Phase change materials

Qpedia Volume 3 topic highlights:

– CFD modeling

– PCB optimization

– Jet impingement cooling

– LED cooling

– Cold plates

– Refrigeration systems

Qpedia Volume 4 topics highlights:

– Multilayer mini-channel heat sinks

– Electro-osmotic pumps

– Thermoelectric coolers

– High altitude heat transfer

– Data center cooling

– Defense electronics

– Automotive electronics cooling

Check out the video on Qpedia Volume 4

Over fifteen thermal and mechanical engineers combined their expertise to create the articles in this useful collection, including Kaveh Azar, Ph.D. and Bahman Tavassoli, Ph.D., both of whom are internationally recognized experts in the field of the thermal management of electronics. Qpedia Thermal eMagazine, published by Advanced Thermal Solutions, Inc. (ATS) was launched in 2007 as a technical publication dedicated to the thermal management of electronics.

Filled with careful explanations, step-by-step calculations, and practical examples from real life challenges, this expert collection of articles is a must have for any mechanical, electrical, and thermal engineer or anyone interested in the rapidly growing field of electronics cooling.

Order the Qpedia Book Series with 25% off now at www.coolingzone.com The books can be purchased as a complete set, combination, or individually. Volume discounts for organizations and academic institutions are also available.

How to Calculate Heat Loads for Liquid Cooling Systems

A series of calculations can be used to find the thermal loads in common liquid cooling systems. Calculations of this nature are needed to predict the performance of liquid cooling systems, which are effective but complex thermal management solutions. Several equations must be calculated to fully understand the behavior of a liquid cooled system, and ATS is providing these to engineers via personal instruction and in a paper available free from the company’s website, Qats.com.

IIn the paper, which appears in the company’s e-magazine, ATS considers a liquid cooling system as a closed loop system with three major components: cold plate, heat exchanger and pump. The cold plate is typically made from aluminum or copper, and is attached to the device being cooled. The plate usually has internal fins which transfer heat to the coolant flowing through them. This fluid moves from the cold plate to a heat exchanger where its heat is transferred to the ambient air via forced convection. The final part of the cooling loop is the pump, which drives the fluid through the loop.

A series of equations is provided to predict the final temperature of the device being cooled. The first of these equates the surface temperature of this device with the product of the power dissipated by the device times the thermal resistance of the cold plate (and its thermal interface material), added to the temperature of the water entering the cold plate.

The sequence of calculations factors in specifications from the cold plate, heat exchanger and pump. The result is a solution for the device temperature as a function of cold plate resistance. In the example cited by ATS, a cold plate thermal resistance of less than 18 degrees C/W is required to cool an Intel Xeon 5492 processor in a 25C temperature environment.

Liquid cooling is an important and expanding practice in the electronics industry. It is important to understand the impact on performance of all three major parts of liquid cooling loops (cold plate, heat exchanger and pump) to ensure an acceptable level of performance at the lowest cost.

Instructions for calculating load for liquid cooling systems are available on Qats.com in the pages of Qpedia, the thermal management emagazine from ATS. More information is also available by calling 1-781-949-2522.

ATS Webinar Selecting and Designing Liquid Cold Plates for Deployment in Electronic Systems

Advanced Thermal Solutions (ATS, Inc. www.qats.com) will be hosting a free webinar, led by Dr. Kaveh Azar, on selecting and designing liquid cold plates for deployment in electronic systems on August 26th at 2PM EST.

This webinar provides the best practices for implementing a liquid cooling system at the device level. Topics covered include:

  • When should you cool with liquid?
  • What is the right liquid cooling system to use?
  • What is a cold plate and how and when to best implement them

To join this webinar on August 26th, click to our web site to register here:  Selecting and Designing Liquid Cold Plates for Deployment in Electronic Systems