• Check Stock
  • Language Icon
  • My Cart My Cart
  • Sign in

Heat pipe performance

ATS Heat Pipe Calculator (TMT)

Heat pipe performance calculator

Enter an ATS part number, or your own geometry, to get thermal resistance (°C/W), a ΔT vs. Q curve, and maximum heat load for your orientation and bends.

Loading catalog…

Heat pipe

Operating conditions

Vapor temp, 30–120
ATS rates its heat pipes at 4 °C.
0 = horizontal. Positive = heat source above the fins (against gravity). Negative = gravity assisted.

Bends

–°C/W
Thermal resistance, evaporator to condenser
–°C
ΔT at your heat load
–W
Max Q, your ΔT limit, orientation and bends
–%
Load as share of max Q

ΔT vs. Q

Layout

Where the resistance comes from

Values are evaporator-to-condenser for copper/water heat pipes and exclude thermal interface and heat sink resistance. For design guidance; ATS test data governs.