ATS-AIC-1011

*Image above is for illustration purpose only..
ATS-AIC-1011
AI Chip Coolers / Direct Liquid Cooling Cold Plate

The ATS-AIC-1011 is a high-performance direct liquid cooling cold plate designed for AMD SP5 socket AI and HPC processors. Built with optimized jet impingement flow geometry, the ATS-AIC-1011 helps remove high processor heat loads while maintaining low thermal resistance and scalable integration into shared liquid cooling systems.

Features & Benefits
  • Designed for AMD SP5 socket AI and HPC processors
  • Jet impingement internal flow design for high heat transfer
  • Compact, precision-machined aluminum cold plate
  • Thermal resistance down to approximately 0.006 °C/W
  • Supports up to 6.5 kW heat dissipation
  • Low pressure drop for multi-device cooling loops
  • Compatible with standard direct-to-chip cooling systems
  • Engineered for AI, HPC, data center, and server platforms
Applications
  • AI inference and training systems
  • HPC processor and accelerator cooling
  • Multi-device and manifolded liquid cooling loops
  • Industrial, defense, and ruggedized electronics
  • Production AI systems requiring reliable operation
Specifications
Part Number Lifecycle
Status
Plate Dimension (mm) Weight (gr) Material Flow Rate
LPM(GPM) 1.0 (0.26)
Flow Rate
LPM(GPM) 2.0 (0.52)
Flow Rate
LPM(GPM) 3.0 (0.79)
Flow Rate
LPM(GPM) 4.0 (1.05)
Length Width Height R
(°C/W)
dP
kPA (psi)
R
(°C/W)
dP
kPA (psi)
R
(°C/W)
dP
kPA (psi)
R
(°C/W)
dP
kPA (psi)
ATS-AIC-1011 ACTIVE 118.0 92.4 30.8 290 Al 0.02 1.38 (0.20) 0.012 4.55 (0.66) 0.009 10.83 (1.57) 0.007 19.79 (2.87)
Thermal Performance
Schematic Image Thermal Resistance
Flow Rate
LPM(GPM)
R
(°C/W)
dP
kPA (psi)

*Image above is for illustration purpose only.
1.0 (0.26) 0.02 1.38 (0.20)
2.0 (0.52) 0.012 4.55 (0.66)
3.0 (0.79) 0.01 (0.00) 10.83 (1.57)
4.0 (1.05) 0.007 19.79 (2.87)
5.0 (1.32) 0.006 28.82(4.18)
6.0 (1.58) 0.006 41.65(6.04)
ATS-AIC-1011    (Data Sheet)
download data sheet
ATS-AIC-1011
CAD MODEL (Fused Model) - use for Form and Fit
Download CAD Model (Fused Model) (used for Form and Fit use)
RoHS & REACH Certificate download data sheet
Complete Your Liquid Loop with ATS

ATS has the products needed to design a complete liquid cooling loop : iCDMs (Industrial Cooling Distribution Modules), Tubed and High Performance Cold Plates to transfer and remove the heat from the source; Heat Exchangers to transfer heat from the liquid to the air with or without a fan; Chillers to circulate and condition the fluid in the system, Compact Refrigeration Modules for very high capacity cooling. In addition , ATS offers Flow Meters to measure the volumetric flow rate of the fluid in the system and Leak Detectors to notify users of any leaks in the system.