• Check Stock
  • Language Icon
  • My Cart My Cart
  • Sign in

CDU-RM250

Liquid Cooling iCDM CDU-RM250
*Image above is for illustration purpose only..
CDU-RM250
iCDM
  • CDU-RM250
  • 0.0 x 0.0 x 0.0 mm
  • Tubing:
  • Download PDF
  • See detail
  • See detail
Features & Benefits
  • Compact Power: 4U rack-mount design delivering up to 235 kW of liquid cooling with 150 LPM facility flow rate at an approach of temperature of 9°C.
  • High Efficiency:Liquid-to-liquid heat exchanger for stable, low-loss thermal transfer.
  • Smart Control:PLC + HMI provide intelligent management and real-time visibility.
  • Reliable Operation:Dual redundant pumps and power supplies ensure uninterrupted cooling.
  
  • Flexible Integration:Designed for seamless connection to facility water loops.
  • Quiet and Efficient:Low-noise, variable-speed pump minimizes energy use.
  • Durable Build:Lightweight, powder-coated aluminum chassis for long-term performance.
  • Maintenance-Friendly:Simplified service design with no filter change requirements.
Applications
  • Cold plate and heat exchanger performance testing
  • Electronics and power-device cooling
  • Immersion cooling evaluation and fluid loop testing
  • Laboratory and industrial R&D setups
  • Portable or auxiliary cooling where facility water is unavailable
 
Specifications
H=Height; W=Width; D=Diameter;WT=Weight(kg); MCC=Maximum Cooling Capacity; CFR=Coolant Flow Rate; RV=Reservoir Volume ; FC=Fluid Connections; PIC=Power Input Current; OE=Operating Environment; OHR=Operating Humidity Range;
Part NumberDIMENSIONS (mm)WTMCCCFRRVFCPICOEOHR
HWD
ATS-CDU-RM250 177.8 482 1186 65 kg 235 kW 137 LPM
(36.2 GPM)
7 L
(1.8 Gal)
1" sanitary flanges
(4 ports)
11 A/115 VAC or 5.5A/230 VAC 4–40°C
(39.2–104°F)
0–90% RH
Specifications
Part Number Lifecycle
Status
Plate Dimension (mm) Overall
Length
(mm)
# No
of Tube
Pass
Tube
Material
Flow Rate
LPM(GPM) 1.9(0.5)
Flow Rate
LPM(GPM) 3.7(1.0)
Flow Rate
LPM(GPM) 5.7(1.5)
Flow Rate
LPM(GPM) 7.6(2.0)
Length Width Height R
(°C/W)
dP
kPA (psi)
R
(°C/W)
dP
kPA (psi)
R
(°C/W)
dP
kPA (psi)
R
(°C/W)
dP
kPA (psi)
CDU-RM250 ACTIVE 0.0 0.0 0.0 N/A N/A AL
Thermal Performance
Schematic Image Thermal Resistance
Flow Rate
LPM(GPM)
R
(°C/W)
dP
kPA (psi)

*Image above is for illustration purpose only.
1.9 (0.5) 0 N/A
3.7 (1.0)
5.7 (1.5)
7.6 (2.0)
CDU-RM250    (Data Sheet)
download data sheet
CDU-RM250
CAD MODEL (Fused Model) - use for Form and Fit
Download CAD Model (Fused Model) (used for Form and Fit use)
Complete Your Liquid Loop with ATS

ATS has the products needed to design a complete liquid cooling loop : iCDMs (Industrial Cooling Distribution Modules), Tubed and High Performance Cold Plates to transfer and remove the heat from the source; Heat Exchangers to transfer heat from the liquid to the air with or without a fan; Chillers to circulate and condition the fluid in the system, Compact Refrigeration Modules for very high capacity cooling. In addition , ATS offers Flow Meters to measure the volumetric flow rate of the fluid in the system and Leak Detectors to notify users of any leaks in the system.