*Image above is for illustration purpose only.. iCDM-10 Industrial Cooling Distribution Module The ATS iCDM-10 is a fully integrated, standalone liquid cooling system designed that features a cooling capacity of 10kW. Housed in a single, ventilated enclosure, it features a built-in pump, heat exchanger, reservoir, and control system, providing a complete liquid loop solution. Simply connect your cold plate or preferred heat removal mechanism, and the system is ready to deliver efficient, high-performance thermal management with minimal setup. This self-contained liquid loop system brings convenience and reliability to cold plate cooling of lasers, computer servers, and heat-challenged equipment used in laboratories, medical diagnostics, defense, aerospace and chip-manufacturing. Features & BenefitsTemperature control by adjusting the flow manually using system VFD controlEnvironmentally friendlyLocalized cooling once attached to a cold plateFast temperature response for cooling. Check Stock & Buy Now Wetted MaterialAluminumEPDMStainless Steel PolycarbonatePolypropylene Polyurethane Nylon 11 Santoprene ApplicationsLaser coolingLaboratory test equipmentMedical diagnostic equipmentAnalytical equipmentDefense & aerospaceSemiconductor equipmentComputer server liquid coolingProduct and How To Videos iCDM DiagramProduct DetailsL=Length; W=Width; H=Height; CC=Cooling Capacity; PPHM=Pump Pressure Head Max; PFR=Pump Flow Rate; WTC=Water Tank Capacity (1/2 gallon); FLA=Fluid Loop Attach; PIC=Power Input Current; FR=Frequency Range; OTR=Operating Temperature Range; OHR=Operating Humidity Range; WT=Weight; ST=Storage Temperature; SH=Storage Humidity; Part NumberLifecycleStatusDIMENSIONS (mm)CC PPHM PFR WTC FLAPICFROTROHRWTSTSHLW H iCDM-10ACTIVE800 550 575 10 kW70 m22 l/min 7.5 L (1.98 gal) 1/2 inch NPT20 A 60 Hz 25 TO 75℃ 20 to 90% RH 54.2 kg -40 to + 85℃ 10 to 95% Complete Your Liquid Loop with ATS ATS has the products needed to design a complete liquid cooling loop : iCDMs (Industrial Cooling Distribution Modules), Tubed and High Performance Cold Plates to transfer and remove the heat from the source; Heat Exchangers to transfer heat from the liquid to the air with or without a fan; Chillers to circulate and condition the fluid in the system, Compact Refrigeration Modules for very high capacity cooling. In addition , ATS offers Flow Meters to measure the volumetric flow rate of the fluid in the system and Leak Detectors to notify users of any leaks in the system. iCDM Cold Plates Vapor Compression Chillers Heat Exchangers TEC Heat and Chillers Flow Meters Leak Detectors Refrigeration Liquid Cooled Heat Sinks Back View Data Sheet Custom Designs Available! Click Here to Contact Us Frequently Asked Questions ? View Similar iCDM-10 iCDM-20
*Image above is for illustration purpose only.. iCDM-10 Industrial Cooling Distribution Module The ATS iCDM-10 is a fully integrated, standalone liquid cooling system designed that features a cooling capacity of 10kW. Housed in a single, ventilated enclosure, it features a built-in pump, heat exchanger, reservoir, and control system, providing a complete liquid loop solution. Simply connect your cold plate or preferred heat removal mechanism, and the system is ready to deliver efficient, high-performance thermal management with minimal setup. This self-contained liquid loop system brings convenience and reliability to cold plate cooling of lasers, computer servers, and heat-challenged equipment used in laboratories, medical diagnostics, defense, aerospace and chip-manufacturing. Features & BenefitsTemperature control by adjusting the flow manually using system VFD controlEnvironmentally friendlyLocalized cooling once attached to a cold plateFast temperature response for cooling. Check Stock & Buy Now Wetted MaterialAluminumEPDMStainless Steel PolycarbonatePolypropylene Polyurethane Nylon 11 Santoprene ApplicationsLaser coolingLaboratory test equipmentMedical diagnostic equipmentAnalytical equipmentDefense & aerospaceSemiconductor equipmentComputer server liquid coolingProduct and How To Videos iCDM DiagramProduct DetailsL=Length; W=Width; H=Height; CC=Cooling Capacity; PPHM=Pump Pressure Head Max; PFR=Pump Flow Rate; WTC=Water Tank Capacity (1/2 gallon); FLA=Fluid Loop Attach; PIC=Power Input Current; FR=Frequency Range; OTR=Operating Temperature Range; OHR=Operating Humidity Range; WT=Weight; ST=Storage Temperature; SH=Storage Humidity; Part NumberLifecycleStatusDIMENSIONS (mm)CC PPHM PFR WTC FLAPICFROTROHRWTSTSHLW H iCDM-10ACTIVE800 550 575 10 kW70 m22 l/min 7.5 L (1.98 gal) 1/2 inch NPT20 A 60 Hz 25 TO 75℃ 20 to 90% RH 54.2 kg -40 to + 85℃ 10 to 95% Complete Your Liquid Loop with ATS ATS has the products needed to design a complete liquid cooling loop : iCDMs (Industrial Cooling Distribution Modules), Tubed and High Performance Cold Plates to transfer and remove the heat from the source; Heat Exchangers to transfer heat from the liquid to the air with or without a fan; Chillers to circulate and condition the fluid in the system, Compact Refrigeration Modules for very high capacity cooling. In addition , ATS offers Flow Meters to measure the volumetric flow rate of the fluid in the system and Leak Detectors to notify users of any leaks in the system. iCDM Cold Plates Vapor Compression Chillers Heat Exchangers TEC Heat and Chillers Flow Meters Leak Detectors Refrigeration Liquid Cooled Heat Sinks
Back View Data Sheet Custom Designs Available! Click Here to Contact Us Frequently Asked Questions ? View Similar iCDM-10 iCDM-20